Used Cleaver Brooks CBLE Boilers for Sale

Boiler Guides

Used Cleaver Brooks CBLE Boilers for Sale

If you searched “Cleaver Brooks CBLE” or “CB-LE,” you are looking at one of the best-known Cleaver Brooks firetube lines. CBLE is the low-emission (LE) version of the Model CB. It is a four-pass, 5 square feet per horsepower firetube built for steam or hot water, with Cleaver-Brooks’ own integral burner and controls in one package.

Boilers.com buys and sells used commercial and industrial boilers and ships nationwide from Miami, Florida. Below is what the CBLE is, how to read a CBLE model number, the used CBLE boilers we have listed right now, and what to check before you buy one.

2015 350 HP Cleaver Brooks CBLE-200-350-150ST firetube steam boiler, 150 PSI, dual fuel
In stock: 2015 Cleaver Brooks CBLE-200-350-150ST, 350 HP, 150 PSI, gas or No. 2 oil, refurbished

What is a Cleaver Brooks CBLE?

The CBLE is a packaged firetube boiler. The pressure vessel, integral forced-draft burner, combustion air fan, burner controls, and trim are designed and shipped as a single unit from one manufacturer. Cleaver-Brooks lists the current CBLE with these ratings:

  • Size: 50 to 800 boiler horsepower.
  • Passes: four-pass, in a waterback or dryback design.
  • Service: steam up to 300 psig, or hot water up to 125 psig.
  • Heating surface: 5 square feet of fireside heating surface per boiler horsepower.
  • Fuels: natural gas or propane, No. 2 and No. 6 oil, or a combination, with alternate fuel capability.
  • Emissions: NOx options of 60, 30, 9, and 5 ppm. On natural gas, Cleaver-Brooks offers packages from 60 ppm down to less than 5 ppm. On No. 2 oil, the published option is less than 70 ppm.
  • Controls: current CBLE packages use Cleaver-Brooks Hawk integrated boiler and burner controls, with an optional variable speed drive on the combustion air fan.

The low-emission design uses induced flue gas recirculation (IFGR). In Cleaver-Brooks’ CB-LE manuals, a transfer port carries relatively cool flue gas from the exit of the fourth-pass tubes to the combustion air fan inlet, and an IFGR damper sets how much is mixed with the incoming air. That lowers the furnace flame temperature, which cuts NOx. That is the main difference between a CBLE and a standard Model CB of the same size. If your plant has an air permit with a NOx limit, the CBLE is usually the first Cleaver Brooks firetube to look at.

Waterback or dryback?

Cleaver-Brooks builds the CBLE both ways. A waterback has a water-cooled rear turnaround, little or no refractory in the rear door, and tubes that are pulled from the front. A dryback is a simpler vessel with a refractory-lined rear door. Opening it gives easy access to the tubes for inspection, cleaning, plugging, or re-rolling, and tubes can be pulled from the front or the back. Ask which design a used unit is, because it changes how the boiler is serviced and how much room you need behind it.

Key specs at a glance

Published Cleaver-Brooks ratings for the current CBLE packaged firetube. A used boiler’s nameplate is the authority for that specific unit.

50 to 800 HPListed size range
Four-passWaterback or dryback firetube
5 sq ft per HPFireside heating surface
Steam to 300 psigOr hot water up to 125 psig
60, 30, 9, and 5 ppmNOx options on natural gas
150 to 350 HPUsed steam units we have listed now

How to read a CBLE model number

A CBLE nameplate model is usually built from the product line, the fuel series, the boiler horsepower, and often the design pressure and service. Take the CBLE-700-150-150ST in our inventory:

  • CBLE is the product line, the low-emission Model CB.
  • 700 is the fuel series. Series 700 is gas only as it left the factory. Other common series are 100 (No. 2 light oil only), 200 (No. 2 oil or gas), 400 (No. 6 heavy oil or gas), and 600 (No. 6 heavy oil only).
  • 150 is the boiler horsepower.
  • 150ST is 150 psig design pressure, steam service. HW in that position would mean hot water.

So a CBLE-200-350-150ST is a 350 HP, gas or No. 2 oil, 150 psig steam boiler. Older units sometimes show the low-emission marking at the end of a Model CB number instead, as in our 1997 CB-I-700-150LE. Searches for “cble 700”, “cble 200”, or “cb le” are usually looking for one of these model numbers.

Two more things to know. First, the horsepower number is not the pressure. Second, the published ratings tie directly to horsepower. One boiler horsepower is 34.5 pounds of steam per hour from and at 212°F, or 33,475 Btu/hr, so a 150 HP CBLE is rated about 5,175 lbs/hr and a 350 HP CBLE about 12,075 lbs/hr. Real output in your plant depends on feedwater temperature, operating pressure, fuel, and condition.

Used Cleaver Brooks CBLE boilers in stock

Every unit below is a used steam boiler listed as available and call for price. Figures come from each listing. Inventory changes, so call (305) 428-2777 to confirm a unit before you plan around it.

ModelHPPSIFuelYearLocationStock / yard tag
CBLE-700-150-150ST150150Natural gas2011CallBSCB150HP2662
CB-I-700-150LE150200Natural gas1997OhioBSCB700HP185
CB200 (CBLE configuration, rebuilt)25015Gas or oil2002OhioBSCB250HP271
CBLE 200-300-150300150Gas or oil2009OhioBHWCB670HP210
CBLE-200-350-150ST (refurbished)350150Gas or No. 2 oil2015OhioBSCB350HP302

150 HP: 2011 CBLE-700-150-150ST

Our 2011 CBLE-700-150-150ST is a 150 HP packaged firetube steam boiler with 150 PSI design pressure, fired on natural gas. Nameplate input is 6,124,000 Btu/hr, and steam output is about 5,175 lbs/hr, matching the Cleaver-Brooks CBLE rating for 150 HP. It has the integral CBLE low-emission burner, a gas manifold pressure of 2.8 in. W.C., and a stack economizer installed. The buyer is responsible for removal, transport, and rigging. For more on this size, see our guide to the Cleaver Brooks CB700-150 and CBLE 700-150.

150 HP, 200 PSI: 1997 CB-I-700-150LE

If you need more than 150 PSI at 150 HP, the 1997 CB-I-700-150LE is a low-emission Model CB rated 200 PSI MAWP. It is natural gas fired, with 6,024,000 Btu/hr input, 750 sq ft of heating surface, and 5,175 lbs/hr maximum design steaming capacity. It was certified by Cleaver-Brooks of Canada Ltd. and carries National Board No. 2643. The listing gives a 10 HP blower motor on 220 V, 3-phase power.

250 HP, low pressure: 2002 CB200 in CBLE configuration

For heating loads, the 2002 CB200 is a 250 HP, 15 PSI low pressure steam boiler listed as a CBLE configuration, dual fuel gas or oil. It was completely rebuilt and never put back into service. The listing shows 460 V, 3-phase power, a 10 HP blower motor, and Cleaver-Brooks emission reduction equipment.

300 HP: 2009 CBLE 200-300-150

The 2009 CBLE 200-300-150 is a 300 HP, 150 PSI steam boiler built in Milwaukee, Wisconsin. Fuel series 200 means natural gas or No. 2 oil. The listing gives a maximum input of 12,247,000 Btu/hr, an oil firing rate of 87.5 GPH, and a gas manifold pressure of 18.5 in. W.C. at sea level. It is listed as currently installed, so ask about removal timing.

350 HP: 2015 CBLE-200-350-150ST, refurbished

The newest CBLE we list is a 2015 CBLE-200-350-150ST built in Thomasville, Georgia. It is 350 HP, 150 PSI steam, dual fuel natural gas or No. 2 oil, with a 30 ppm NOx rating and a gross output of 11,716,000 Btu/hr. Gas input runs from 1,429,000 to 14,288,000 Btu/hr, and oil input from 12.8 to 102.1 GPH. It has been refurbished with new controls, including a Hawk touchscreen burner control interface and an Allen-Bradley PowerFlex 400 variable frequency drive on the combustion air blower.

Need a different size? Browse all used Cleaver Brooks boilers, our used Cleaver Brooks 150 HP boilers, or every used boiler we have. We also list newer low-NOx Cleaver Brooks firetubes outside the CBLE line, including CBEX units.

Typical uses for a CBLE

Cleaver-Brooks lists the CBLE for process steam, industrial process loads, building heat, sterilization, humidification, hospitals and healthcare, and laundry and dry cleaning. In practice, the 150 to 350 HP units we see most often come out of hospitals, schools and campuses, food plants, and mid-size manufacturing. Low pressure 15 psig units are usually heating boilers. 150 psig and higher units are usually process boilers. A firetube’s large water volume helps it ride through load swings with steadier steam pressure.

What to check when buying a used CBLE

A CBLE that has been maintained and fed treated water can run for decades. The risk is buying from photos and a spec sheet alone. Inspect the boiler in person, or have a qualified inspector do it, and match every claim to the nameplate and the records.

We can help arrange an inspection and quote freight and rigging with the boiler.

FAQ

What does CBLE stand for on a Cleaver Brooks boiler?

CBLE is the low-emission (LE) version of the Cleaver Brooks Model CB packaged firetube. It uses induced flue gas recirculation (IFGR) to reduce NOx, with options from 60 ppm down to less than 5 ppm on natural gas.

Is the CBLE a four-pass boiler?

Yes. Cleaver-Brooks lists the CBLE as a four-pass firetube, available as a waterback or dryback, with 5 square feet of heating surface per boiler horsepower.

What sizes does the CBLE come in?

Cleaver-Brooks lists 50 to 800 HP, steam up to 300 psig or hot water up to 125 psig. The used CBLE units we have now are 150, 250, 300, and 350 HP steam boilers.

What is the difference between a CB and a CBLE?

Both are Cleaver Brooks four-pass packaged firetubes. The CBLE adds the low-emission burner system to cut NOx. If you have an emissions limit, start with a CBLE and still get the unit’s documented NOx rating.

How much does a used CBLE cost?

It depends on size, year, pressure, fuel, NOx rating, condition, and what is included. Our CBLE listings are call for price. Call (305) 428-2777 or use our contact page with the unit you are looking at.

Do you buy used CBLE boilers?

Yes. We buy Cleaver Brooks boilers, including CBLEs, nationwide. Send the nameplate photo, location, and condition through our we buy boilers page.

Find the right used CBLE

Start with the 2011 CBLE-700-150-150ST, the 2009 CBLE 200-300-150, or the refurbished 2015 CBLE-200-350-150ST, or browse all used Cleaver Brooks boilers. Tell us the horsepower, pressure, fuel, NOx limit, and timing you need, and we will confirm what is in stock or source one. Contact us or call (305) 428-2777. We serve plants nationwide from Miami, Florida.

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *