Used Cleaver Brooks Boilers for Sale
Cleaver Brooks boilers make up most of what we buy and sell. Right now our used Cleaver Brooks inventory runs from small 60 HP packaged firetubes up to a 1,500 HP CBEX, plus two Cleaver Brooks watertube boilers. Most are high pressure steam units at 150 to 250 PSI, and a few are 15 PSI low pressure steam boilers for heating.
Boilers.com buys, sells, and rents commercial and industrial boilers from Miami, Florida, and ships nationwide. Below is our current Cleaver Brooks inventory by size, a plain guide to the model lines and model numbers you will see on these boilers, and what to check before you buy. If you have a Cleaver Brooks boiler to sell, we buy them too.
Current Cleaver Brooks Inventory

200 HP Cleaver Brooks CBE100-200 Firetube Steam Boiler #BSCB200HP6332

500 HP Cleaver Brooks CBEX-2W-700-500-150 Firetube Steam Boiler #BSCB500HP9058

60 HP Cleaver Brooks CBH 700-60 Firetube Steam Boiler #BSCB60HP9033

800 HP Cleaver Brooks CBEX-2D 200-800-150ST Firetube Steam Boiler #BSCB800HP9182

80 HP Cleaver Brooks CB 700-80 Firetube Steam Boiler #BSCB80HP1295

Other HP Cleaver Brooks CBEX-2W 700-1500-150ST Firetube Steam Boiler #BSCB1500HP8882

Other HP Cleaver Brooks DELTA 60 Watertube Steam Boiler #CHPPV2019305

200 HP Cleaver Brooks CBEX-P700-200-150 Firetube Steam Boiler #BSCB200HP4340

150 HP Cleaver Brooks CBLE-700-150-150ST Firetube Steam Boiler #BSCB150HP2662

125 HP Cleaver Brooks CB 400-125-250 ST Firetube Steam Boiler #BSCB250PSI92995

500 HP Cleaver Brooks CBW 700-500 Firetube Steam Boiler #BSCB700HP186
All used Cleaver Brooks boilers by size
Every unit below is listed as available and is call for price. Figures come from each listing. Where a listing gives two different values, the cell says “Call to confirm.” Inventory changes, so call 305-428-2777 to confirm a unit before you plan around it. You can also browse our used Cleaver Brooks 100 HP boilers and used Cleaver Brooks 150 HP boilers pages.
Up to 100 HP
| Model | HP | PSI | Fuel | Year | Location | Stock / yard tag |
|---|---|---|---|---|---|---|
| CB-60-50 | Call to confirm | Call to confirm | Natural gas | Call to confirm | Ohio | BSCB60HP193 |
| CBH 700-60 | 60 | 150 | Natural gas | 1980 | Miami, FL | BSCB60HP9033 |
| CB 700-80 | 80 | 150 | Natural gas | 1992 | Miami, FL | BSCB80HP1295 |
| CB700X-99-P | 100 | 15 | Natural gas | 2012 | Ohio | BSCB100HP189 |
| CBW-700-100-150-ST | 100 | 150 | Natural gas | 1995 | Ohio | BSCB100HP290 |
| CB-900-100 (in a 40 ft container) | 100 | 15 | Gas or oil | 1979 | Ohio | BSCB100HP300 |
125 to 200 HP
| Model | HP | PSI | Fuel | Year | Location | Stock / yard tag |
|---|---|---|---|---|---|---|
| CB 400-125-250 ST | 125 | 250 | Not on the tag | 2019 | Call | BSCB250PSI92995 |
| CBLE-700-150-150ST | 150 | 150 | Natural gas | 2011 | Call | BSCB150HP2662 |
| CB-I-700-150LE | 150 | 200 | Natural gas | 1997 | Ohio | BSCB700HP185 |
| CB700-150 (containerized) | 150 | 150 | No. 2 oil (converted from gas) | 1988 | Ohio | B150HPSCB150PSI022 |
| CB-200-150 | 150 | 150 | Gas or No. 2 oil | 1992 | Ohio | BSCB150HP296 |
| CBE100-200 (quantity of two) | 200 | 150 | No. 2 oil | 1997 | New Hampshire | BSCB200HP6332 |
| CB-100-200 | 200 | 150 | Call to confirm | 1981 | Ohio | BSCB250HP246 |
| CB-500-200C (in a 40 ft trailer) | 200 | 150 | Gas or No. 2 oil | 1982 (nameplate) | Ohio | BSCB200HP282 |
| CB700-200-200 | 200 | 200 | Natural gas | Call to confirm | Ohio | BSCB200HP192 |
| CB-700-200 | 200 | 150 | Natural gas | 1988 | Call to confirm | BSCB200HP273 |
| CBEX-P700-200-150 | 200 | 150 | Natural gas | 2014 | Call | BSCB200HP4340 |
250 to 350 HP
| Model | HP | PSI | Fuel | Year | Location | Stock / yard tag |
|---|---|---|---|---|---|---|
| CB 655-250 | 250 | 150 | Call to confirm | 1971 | Miami, FL | 9978t66 |
| CB-200-250 | 250 | 150 | Gas or oil | Call to confirm | Ohio | BSCB250HP188 |
| CB 700-250-150 | 250 | 150 | Natural gas | 2005 | Ohio | BSCB700HP213 |
| CB200 (rebuilt, CBLE configuration) | 250 | 15 | Gas or oil | 2002 | Ohio | BSCB250HP271 |
| CB200-250-015 | 250 | 15 | Gas or No. 2 oil | 2001 | Ohio | BPSDM302006289 |
| CBLE 200-300-150 | 300 | 150 | Gas or oil | 2009 | Ohio | BHWCB670HP210 |
| CBLX E 200 300-150ST | 300 | 150 | Gas or oil | 2017 | Ohio | BSCB300HP223 |
| CB-400-350-150 | 350 | 150 | Natural gas | Call to confirm | Ohio | BSCB350HP214 |
| CBLE-200-350-150ST (refurbished) | 350 | 150 | Gas or No. 2 oil | 2015 | Ohio | BSCB350HP302 |
400 to 800 HP
| Model | HP | PSI | Fuel | Year | Location | Stock / yard tag |
|---|---|---|---|---|---|---|
| CB 200X-440-200ST (with economizer) | 440 | 200 | Natural gas | 2017 | Ohio | BSCB200HP187 |
| CBEX-2W-700-500-150 | 500 | 150 | Natural gas | 2022 | Colorado | BSCB500HP9058 |
| CBW 700-500 | 500 | 150 | Natural gas | 2002 | Ohio | BSCB700HP186 |
| CB-600-600 | 600 | 150 | No. 2 oil | 1979 | Ohio | BSCB600HP266 |
| CBEX-E700-700-150ST | 700 | 150 | Natural gas | 2020 | Ohio | BSCB700HP205 |
| CBEX-E-700-700-250ST | 700 | 250 | Natural gas | Call to confirm | Ohio | BSCB700HP294 |
| CBL-700-720-200 | Call to confirm | 200 | Natural gas | 2007 | Ohio | CMRTM4500208 |
| 4WG-200-800-150 | 800 | 150 | Natural gas | 2004 | Ohio | BSCB800HP232 |
| CBEX-2D 200-800-150ST | 800 | 150 | Gas or No. 2 oil | 2023 | Miami, FL | BSCB800HP9182 |
Over 800 HP, and watertube boilers
| Model | HP | PSI | Fuel | Year | Location | Stock / yard tag |
|---|---|---|---|---|---|---|
| CBEX-2W 700-1500-150ST | 1,500 | 150 | Natural gas | 2022 | Call | BSCB1500HP8882 |
| NB-100D-35 (Nebraska D-type watertube) | 600 | 250 | Natural gas | 2013 | Call to confirm | B600HPSCB250PSI028 |
| Delta 60 watertube (31,000 lb/hr) | Not stated | 350 | Not specified | 2010 | Mexico | CHPPV2019305 |
Cleaver Brooks model lines you will see
- CB. The classic Cleaver Brooks packaged firetube, built as one unit with the pressure vessel, integral burner, and controls. Most of the older units above, from the 1971 CB 655-250 to the 2005 CB 700-250-150, are Model CB boilers. CBW on a nameplate marks a wetback design. Our 1995 CBW-700-100-150-ST is listed as a four-pass wetback.
- CBLE. The low-emission version of the CB. Cleaver-Brooks lists the CBLE as a four-pass firetube from 50 to 800 HP, steam up to 300 psig or hot water up to 125 psig, in waterback or dryback designs, with five square feet of heating surface per boiler horsepower. NOx options of 60, 30, 9, and 5 ppm are available. We list a 2011 CBLE-700-150-150ST, a 2009 CBLE 200-300-150, a 2015 CBLE-200-350-150ST, and a 1997 CB-I-700-150LE.
- CBEX. Cleaver-Brooks’ newer integrated boiler, burner, and control package. Cleaver-Brooks lists it from 100 to 2,500 HP in two-pass and three-pass designs, steam up to 300 psig, with 30 ppm NOx standard across a 10:1 turndown and sub-5 ppm NOx available on most models. In the model number, 2W is the two-pass waterback and 2D is the two-pass dryback. Our CBEX units run from a 2014 CBEX-P700-200-150 to a 2023 CBEX-2D 800 HP and a 2022 CBEX-2W 1,500 HP.
- Watertube boilers. Cleaver Brooks also builds industrial watertubes. We list a 2013 NB-100D-35 D-type watertube built by Cleaver-Brooks in Lincoln, Nebraska, at 250 PSIG, and a 2010 Delta 60 watertube rated 31,000 lb/hr of steam at 350 PSI. If you are not sure which design fits your plant, see firetube vs watertube boilers.
How to read a Cleaver Brooks model number
On CB and CBLE boilers, the model number is usually the product line, the fuel series, the boiler horsepower, and sometimes the design pressure and service. Take the CBLE-200-350-150ST:
- CBLE is the product line.
- 200 is the fuel series. Series 200 fires No. 2 oil or gas. Series 700 is gas only as built. Other common series are 100 (No. 2 oil only), 400 (No. 6 oil or gas), and 600 (No. 6 oil only).
- 350 is the boiler horsepower.
- 150ST means 150 psig design pressure, steam.
The horsepower number is not the pressure. A 150 HP boiler can be built for 150 or 200 PSI, and our CB-I-700-150LE is a 150 HP boiler rated 200 PSI. A fuel series tells you how a boiler left the factory, not how it runs today. Our 1988 CB700-150 was built as a gas-fired series 700 and has since been converted to No. 2 oil. Always read the nameplate. For a worked example, see our Cleaver Brooks CB700-150 guide.
Low pressure Cleaver Brooks boilers (15 PSI)
Low pressure steam boilers are typically used for building heat, not high pressure process loads. Our 15 PSI Cleaver Brooks units are:
- A 2012 CB700X-99-P, 100 HP, natural gas, with an input of 4,142,531 Btu/hr.
- A 1979 CB-900-100, 100 HP, gas or oil, mounted in a 40 ft container with its fuel tank, feedwater tank, preheat tank, and a spare fuel pump.
- A 2001 CB200-250-015, 250 HP, natural gas or No. 2 oil, input 10,206,800 Btu/hr, moved from service in April 2026.
- A 2002 CB200, 250 HP in a CBLE configuration, dual fuel, completely rebuilt and never put back into service.
Refurbished and rebuilt Cleaver Brooks boilers
Two of our Cleaver Brooks units have had major work done since they left service:
- The 2015 CBLE-200-350-150ST, 350 HP, 150 PSI steam, dual fuel with a 30 ppm NOx rating, has been refurbished and fitted with updated controls, including a Hawk touchscreen burner management interface and an Allen-Bradley PowerFlex 400 variable frequency drive.
- The 2002 CB200, 250 HP, 15 PSI steam, was completely rebuilt and never put back into service.
“Refurbished” can mean anything from new controls to a retube, so ask for the work records on any rebuilt boiler, ours included.
Low NOx Cleaver Brooks boilers
If your plant has an emissions limit, start with a unit that has a documented NOx rating. These listings show one:
- 2023 CBEX-2D 200-800-150ST, 800 HP, natural gas and No. 2 oil, 9 ppm NOx on the nameplate.
- CBEX-E-700-700-250ST, 700 HP, 250 PSI steam, natural gas, with an ultra-low NOx burner rated 5 ppm, a Hawk touchscreen control, and an Allen-Bradley PowerFlex 400 VFD.
- 2020 CBEX-E700-700-150ST, 700 HP, 150 PSI steam, natural gas, 30 ppm NOx.
- 2022 CBEX-2W-700-500-150, 500 HP, 150 PSI steam, natural gas, 30 ppm NOx on the nameplate, located in Colorado.
- 2015 CBLE-200-350-150ST, 350 HP, dual fuel, 30 ppm NOx.
Mobile and containerized Cleaver Brooks boilers
Three of our Cleaver Brooks units are built to move:
- The CB-500-200C, 200 HP, is a complete mobile steam plant inside a 40 ft insulated trailer, and the trailer is included. It is dual fuel, natural gas and No. 2 oil, with feedwater, water softening, and fuel tanks on board.
- The 1988 CB700-150, 150 HP, 150 PSI, runs on No. 2 oil and is housed in a containerized boiler room.
- The 1979 CB-900-100, 100 HP, 15 PSI, is mounted in a 40 ft container.
If you only need steam for a while, see our boiler rentals.
What to check before you buy a used Cleaver Brooks boiler
- Nameplate. Match the model, horsepower, design pressure, steam or hot water, fuel, serial number, and year to the listing. If a listing and the nameplate disagree, the nameplate wins.
- ASME and National Board paperwork. Look for a legible ASME nameplate and a National Board number, plus inspection and repair records. Your insurer and your state inspector will usually ask for them.
- Fuel and burner. Confirm the burner fires the fuel you have. Ask what was changed on any converted boiler.
- Fireside and waterside. Open the doors. Look at the tubes, tube sheets, furnace, and refractory, and ask whether the boiler has been retubed. Scale and corrosion on the waterside point to poor water treatment.
- Controls and safeties. Ask about the flame safeguard, low water cutoffs, and safety valves, and when they were last tested or replaced.
- Emissions. If you have a NOx limit, get the documented rating for that unit, not just the model line.
- What is included and who moves it. Confirm whether feedwater equipment, an economizer, or a container comes with the boiler. On many of our listings the buyer handles removal, transport, and rigging, so ask us to include freight in the quote if you need delivery.
We can help arrange an inspection on any unit we list.
We buy used Cleaver Brooks boilers
Decommissioning a plant or replacing a boiler? We buy used Cleaver Brooks boilers nationwide, from single packaged firetubes to whole boiler rooms. Send us the nameplate photo, location, and a few pictures through our we buy boilers page.
FAQ
Do you have used Cleaver Brooks CBLE boilers?
Yes. We currently list a 150 HP CBLE-700-150-150ST, a 300 HP CBLE 200-300-150, a refurbished 350 HP CBLE-200-350-150ST, and a 150 HP CB-I-700-150LE. Tell us your pressure and fuel and we will match one, or source one if none fits.
How much does a used Cleaver Brooks boiler cost?
It depends on the size, year, condition, pressure, fuel, and what is included. Our listings are call for price, so call 305-428-2777 or use the form below with the unit you are looking at.
Do you ship used boilers?
Yes. We ship nationwide. Most of our Cleaver Brooks units are in Ohio, with others in Miami, Colorado, New Hampshire, and Mexico. Tell us your delivery address and we will quote freight with the boiler.
What if the size I need is not listed?
Call us. We buy Cleaver Brooks boilers all the time and can often source a specific size, pressure, or fuel.
Do you rent Cleaver Brooks boilers?
See our boiler rentals page for the rental units we list now and the mobile Cleaver Brooks units you can buy outright.
Browse all used boilers for sale, or reach us any time through our contact page or at 305-428-2777.
Request a Quote
Tell us what you need — horsepower, pressure, fuel — and we’ll respond fast with pricing and availability.