Used Inventory

Used Cleaver Brooks Boilers for Sale

Cleaver Brooks boilers make up most of what we buy and sell. Right now our used Cleaver Brooks inventory runs from small 60 HP packaged firetubes up to a 1,500 HP CBEX, plus two Cleaver Brooks watertube boilers. Most are high pressure steam units at 150 to 250 PSI, and a few are 15 PSI low pressure steam boilers for heating.

Boilers.com buys, sells, and rents commercial and industrial boilers from Miami, Florida, and ships nationwide. Below is our current Cleaver Brooks inventory by size, a plain guide to the model lines and model numbers you will see on these boilers, and what to check before you buy. If you have a Cleaver Brooks boiler to sell, we buy them too.

2023 800 HP Cleaver Brooks CBEX-2D 200-800-150ST firetube steam boiler, 150 PSI, dual fuel, in Miami
In stock in Miami: 2023 Cleaver Brooks CBEX-2D 200-800-150ST, 800 HP, 150 PSI, dual fuel

Current Cleaver Brooks Inventory

All used Cleaver Brooks boilers by size

Every unit below is listed as available and is call for price. Figures come from each listing. Where a listing gives two different values, the cell says “Call to confirm.” Inventory changes, so call 305-428-2777 to confirm a unit before you plan around it. You can also browse our used Cleaver Brooks 100 HP boilers and used Cleaver Brooks 150 HP boilers pages.

Up to 100 HP

ModelHPPSIFuelYearLocationStock / yard tag
CB-60-50Call to confirmCall to confirmNatural gasCall to confirmOhioBSCB60HP193
CBH 700-6060150Natural gas1980Miami, FLBSCB60HP9033
CB 700-8080150Natural gas1992Miami, FLBSCB80HP1295
CB700X-99-P10015Natural gas2012OhioBSCB100HP189
CBW-700-100-150-ST100150Natural gas1995OhioBSCB100HP290
CB-900-100 (in a 40 ft container)10015Gas or oil1979OhioBSCB100HP300

125 to 200 HP

ModelHPPSIFuelYearLocationStock / yard tag
CB 400-125-250 ST125250Not on the tag2019CallBSCB250PSI92995
CBLE-700-150-150ST150150Natural gas2011CallBSCB150HP2662
CB-I-700-150LE150200Natural gas1997OhioBSCB700HP185
CB700-150 (containerized)150150No. 2 oil (converted from gas)1988OhioB150HPSCB150PSI022
CB-200-150150150Gas or No. 2 oil1992OhioBSCB150HP296
CBE100-200 (quantity of two)200150No. 2 oil1997New HampshireBSCB200HP6332
CB-100-200200150Call to confirm1981OhioBSCB250HP246
CB-500-200C (in a 40 ft trailer)200150Gas or No. 2 oil1982 (nameplate)OhioBSCB200HP282
CB700-200-200200200Natural gasCall to confirmOhioBSCB200HP192
CB-700-200200150Natural gas1988Call to confirmBSCB200HP273
CBEX-P700-200-150200150Natural gas2014CallBSCB200HP4340

250 to 350 HP

ModelHPPSIFuelYearLocationStock / yard tag
CB 655-250250150Call to confirm1971Miami, FL9978t66
CB-200-250250150Gas or oilCall to confirmOhioBSCB250HP188
CB 700-250-150250150Natural gas2005OhioBSCB700HP213
CB200 (rebuilt, CBLE configuration)25015Gas or oil2002OhioBSCB250HP271
CB200-250-01525015Gas or No. 2 oil2001OhioBPSDM302006289
CBLE 200-300-150300150Gas or oil2009OhioBHWCB670HP210
CBLX E 200 300-150ST300150Gas or oil2017OhioBSCB300HP223
CB-400-350-150350150Natural gasCall to confirmOhioBSCB350HP214
CBLE-200-350-150ST (refurbished)350150Gas or No. 2 oil2015OhioBSCB350HP302

400 to 800 HP

ModelHPPSIFuelYearLocationStock / yard tag
CB 200X-440-200ST (with economizer)440200Natural gas2017OhioBSCB200HP187
CBEX-2W-700-500-150500150Natural gas2022ColoradoBSCB500HP9058
CBW 700-500500150Natural gas2002OhioBSCB700HP186
CB-600-600600150No. 2 oil1979OhioBSCB600HP266
CBEX-E700-700-150ST700150Natural gas2020OhioBSCB700HP205
CBEX-E-700-700-250ST700250Natural gasCall to confirmOhioBSCB700HP294
CBL-700-720-200Call to confirm200Natural gas2007OhioCMRTM4500208
4WG-200-800-150800150Natural gas2004OhioBSCB800HP232
CBEX-2D 200-800-150ST800150Gas or No. 2 oil2023Miami, FLBSCB800HP9182

Over 800 HP, and watertube boilers

ModelHPPSIFuelYearLocationStock / yard tag
CBEX-2W 700-1500-150ST1,500150Natural gas2022CallBSCB1500HP8882
NB-100D-35 (Nebraska D-type watertube)600250Natural gas2013Call to confirmB600HPSCB250PSI028
Delta 60 watertube (31,000 lb/hr)Not stated350Not specified2010MexicoCHPPV2019305

Cleaver Brooks model lines you will see

  • CB. The classic Cleaver Brooks packaged firetube, built as one unit with the pressure vessel, integral burner, and controls. Most of the older units above, from the 1971 CB 655-250 to the 2005 CB 700-250-150, are Model CB boilers. CBW on a nameplate marks a wetback design. Our 1995 CBW-700-100-150-ST is listed as a four-pass wetback.
  • CBLE. The low-emission version of the CB. Cleaver-Brooks lists the CBLE as a four-pass firetube from 50 to 800 HP, steam up to 300 psig or hot water up to 125 psig, in waterback or dryback designs, with five square feet of heating surface per boiler horsepower. NOx options of 60, 30, 9, and 5 ppm are available. We list a 2011 CBLE-700-150-150ST, a 2009 CBLE 200-300-150, a 2015 CBLE-200-350-150ST, and a 1997 CB-I-700-150LE.
  • CBEX. Cleaver-Brooks’ newer integrated boiler, burner, and control package. Cleaver-Brooks lists it from 100 to 2,500 HP in two-pass and three-pass designs, steam up to 300 psig, with 30 ppm NOx standard across a 10:1 turndown and sub-5 ppm NOx available on most models. In the model number, 2W is the two-pass waterback and 2D is the two-pass dryback. Our CBEX units run from a 2014 CBEX-P700-200-150 to a 2023 CBEX-2D 800 HP and a 2022 CBEX-2W 1,500 HP.
  • Watertube boilers. Cleaver Brooks also builds industrial watertubes. We list a 2013 NB-100D-35 D-type watertube built by Cleaver-Brooks in Lincoln, Nebraska, at 250 PSIG, and a 2010 Delta 60 watertube rated 31,000 lb/hr of steam at 350 PSI. If you are not sure which design fits your plant, see firetube vs watertube boilers.

How to read a Cleaver Brooks model number

On CB and CBLE boilers, the model number is usually the product line, the fuel series, the boiler horsepower, and sometimes the design pressure and service. Take the CBLE-200-350-150ST:

  • CBLE is the product line.
  • 200 is the fuel series. Series 200 fires No. 2 oil or gas. Series 700 is gas only as built. Other common series are 100 (No. 2 oil only), 400 (No. 6 oil or gas), and 600 (No. 6 oil only).
  • 350 is the boiler horsepower.
  • 150ST means 150 psig design pressure, steam.

The horsepower number is not the pressure. A 150 HP boiler can be built for 150 or 200 PSI, and our CB-I-700-150LE is a 150 HP boiler rated 200 PSI. A fuel series tells you how a boiler left the factory, not how it runs today. Our 1988 CB700-150 was built as a gas-fired series 700 and has since been converted to No. 2 oil. Always read the nameplate. For a worked example, see our Cleaver Brooks CB700-150 guide.

Low pressure Cleaver Brooks boilers (15 PSI)

Low pressure steam boilers are typically used for building heat, not high pressure process loads. Our 15 PSI Cleaver Brooks units are:

  • A 2012 CB700X-99-P, 100 HP, natural gas, with an input of 4,142,531 Btu/hr.
  • A 1979 CB-900-100, 100 HP, gas or oil, mounted in a 40 ft container with its fuel tank, feedwater tank, preheat tank, and a spare fuel pump.
  • A 2001 CB200-250-015, 250 HP, natural gas or No. 2 oil, input 10,206,800 Btu/hr, moved from service in April 2026.
  • A 2002 CB200, 250 HP in a CBLE configuration, dual fuel, completely rebuilt and never put back into service.

Refurbished and rebuilt Cleaver Brooks boilers

Two of our Cleaver Brooks units have had major work done since they left service:

  • The 2015 CBLE-200-350-150ST, 350 HP, 150 PSI steam, dual fuel with a 30 ppm NOx rating, has been refurbished and fitted with updated controls, including a Hawk touchscreen burner management interface and an Allen-Bradley PowerFlex 400 variable frequency drive.
  • The 2002 CB200, 250 HP, 15 PSI steam, was completely rebuilt and never put back into service.

“Refurbished” can mean anything from new controls to a retube, so ask for the work records on any rebuilt boiler, ours included.

Low NOx Cleaver Brooks boilers

If your plant has an emissions limit, start with a unit that has a documented NOx rating. These listings show one:

  • 2023 CBEX-2D 200-800-150ST, 800 HP, natural gas and No. 2 oil, 9 ppm NOx on the nameplate.
  • CBEX-E-700-700-250ST, 700 HP, 250 PSI steam, natural gas, with an ultra-low NOx burner rated 5 ppm, a Hawk touchscreen control, and an Allen-Bradley PowerFlex 400 VFD.
  • 2020 CBEX-E700-700-150ST, 700 HP, 150 PSI steam, natural gas, 30 ppm NOx.
  • 2022 CBEX-2W-700-500-150, 500 HP, 150 PSI steam, natural gas, 30 ppm NOx on the nameplate, located in Colorado.
  • 2015 CBLE-200-350-150ST, 350 HP, dual fuel, 30 ppm NOx.

Mobile and containerized Cleaver Brooks boilers

Three of our Cleaver Brooks units are built to move:

  • The CB-500-200C, 200 HP, is a complete mobile steam plant inside a 40 ft insulated trailer, and the trailer is included. It is dual fuel, natural gas and No. 2 oil, with feedwater, water softening, and fuel tanks on board.
  • The 1988 CB700-150, 150 HP, 150 PSI, runs on No. 2 oil and is housed in a containerized boiler room.
  • The 1979 CB-900-100, 100 HP, 15 PSI, is mounted in a 40 ft container.

If you only need steam for a while, see our boiler rentals.

What to check before you buy a used Cleaver Brooks boiler

  1. Nameplate. Match the model, horsepower, design pressure, steam or hot water, fuel, serial number, and year to the listing. If a listing and the nameplate disagree, the nameplate wins.
  2. ASME and National Board paperwork. Look for a legible ASME nameplate and a National Board number, plus inspection and repair records. Your insurer and your state inspector will usually ask for them.
  3. Fuel and burner. Confirm the burner fires the fuel you have. Ask what was changed on any converted boiler.
  4. Fireside and waterside. Open the doors. Look at the tubes, tube sheets, furnace, and refractory, and ask whether the boiler has been retubed. Scale and corrosion on the waterside point to poor water treatment.
  5. Controls and safeties. Ask about the flame safeguard, low water cutoffs, and safety valves, and when they were last tested or replaced.
  6. Emissions. If you have a NOx limit, get the documented rating for that unit, not just the model line.
  7. What is included and who moves it. Confirm whether feedwater equipment, an economizer, or a container comes with the boiler. On many of our listings the buyer handles removal, transport, and rigging, so ask us to include freight in the quote if you need delivery.

We can help arrange an inspection on any unit we list.

We buy used Cleaver Brooks boilers

Decommissioning a plant or replacing a boiler? We buy used Cleaver Brooks boilers nationwide, from single packaged firetubes to whole boiler rooms. Send us the nameplate photo, location, and a few pictures through our we buy boilers page.

FAQ

Do you have used Cleaver Brooks CBLE boilers?

Yes. We currently list a 150 HP CBLE-700-150-150ST, a 300 HP CBLE 200-300-150, a refurbished 350 HP CBLE-200-350-150ST, and a 150 HP CB-I-700-150LE. Tell us your pressure and fuel and we will match one, or source one if none fits.

How much does a used Cleaver Brooks boiler cost?

It depends on the size, year, condition, pressure, fuel, and what is included. Our listings are call for price, so call 305-428-2777 or use the form below with the unit you are looking at.

Do you ship used boilers?

Yes. We ship nationwide. Most of our Cleaver Brooks units are in Ohio, with others in Miami, Colorado, New Hampshire, and Mexico. Tell us your delivery address and we will quote freight with the boiler.

What if the size I need is not listed?

Call us. We buy Cleaver Brooks boilers all the time and can often source a specific size, pressure, or fuel.

Do you rent Cleaver Brooks boilers?

See our boiler rentals page for the rental units we list now and the mobile Cleaver Brooks units you can buy outright.

Browse all used boilers for sale, or reach us any time through our contact page or at 305-428-2777.

Request a Quote

Tell us what you need — horsepower, pressure, fuel — and we’ll respond fast with pricing and availability.

Contact Form Demo