Refurbished and Clearance Boilers for Sale

Boiler Guides

Refurbished and Clearance Boilers for Sale

“Refurbished boiler” and “clearance boilers” sound like simple labels, but they cover a lot of ground. One seller’s refurbished unit has a rebuilt burner, new controls, and documented tube work. Another’s has a fresh coat of paint. A clearance boiler might be new surplus that was never installed, or an older unit priced to move.

Boilers.com buys and sells used commercial and industrial boilers and ships nationwide from Miami, Florida. Here is what refurbished, reconditioned, and clearance usually mean, the refurbished and surplus boilers we have listed right now, and what to ask before you buy.

Refurbished 2015 350 HP Cleaver Brooks CBLE 200-350-150ST firetube steam boiler with new controls
In stock: refurbished 2015 Cleaver Brooks CBLE 200-350-150ST, 350 HP, 150 PSI, dual fuel, with new controls

Refurbished, reconditioned, rebuilt, or surplus?

There is no single industry definition of a “refurbished” or “reconditioned” boiler. The words describe what the seller says was done, so the work itself is what you are buying. These are the terms you will see most often:

  • Refurbished or reconditioned. The boiler was cleaned up and some parts were repaired or replaced. That can be anything from new controls to new tubes and refractory. Ask for a written list of the work.
  • Rebuilt. Usually a deeper job, with major systems taken apart and repaired or replaced. Again, the scope varies by seller.
  • New surplus or new/unused. A boiler that was built but never installed, or barely run, for example left over from a cancelled or changed project.
  • Clearance. A pricing term, not a condition. It tells you the seller wants the unit gone. It says nothing about what was done to it.

One thing is not up to the seller. Repairs and alterations to the pressure-retaining parts of a boiler, such as tube replacement or welding on the shell, are governed by the National Board Inspection Code (NBIC) Part 3. The National Board issues an “R” Certificate of Authorization to organizations that do this work. To hold it, an organization must keep an inspection agreement with an Authorized Inspection Agency and a written quality system that complies with the NBIC. If a seller says pressure-part work was done, ask who did it and for the R-1 (repair) or R-2 (alteration) report.

What to ask the seller

A refurbished or clearance boiler is only worth the price if the work and the condition are documented. These are the questions the article recommends asking before you buy.

  1. A written scope of work. Ask for a list of exactly what was repaired or replaced, when, and by whom.
  2. Pressure-part repairs. If tubes, the furnace, or the shell were repaired, ask for the NBIC R-1 or R-2 report and the name of the R certificate holder that did the work.
  3. Nameplate, ASME, and National Board identification. Confirm the manufacturer, model, serial number, year, horsepower, and design pressure, plus a legible ASME nameplate and National Board number. When a listing’s figures disagree, the nameplate wins.
  4. Whether any warranty applies. Do not assume a new surplus boiler is under warranty. Ask the seller and the manufacturer in writing.
  5. Pressure and load. A 15 PSI low pressure boiler will not serve a 125 PSI process. Size from your steam load in lbs/hr at your operating pressure.

Refurbished and surplus boilers in stock

Here is a sample of current listings whose condition is listed as refurbished, rebuilt, like new, or new surplus. Figures come from each listing’s nameplate or listing data. Inventory changes often, so browse all used boilers and used Cleaver Brooks boilers, or call for the latest.

2015 Cleaver Brooks CBLE 200-350-150ST, refurbished with new controls

A refurbished Cleaver Brooks CBLE 200-350-150ST (stock BSCB350HP302), located in Ohio. It is a 350 HP packaged firetube steam boiler built by Cleaver Brooks in Thomasville, Georgia, in 2015, serial number T4843-1-1. It is rated 150 PSI steam, dual fuel (natural gas or No. 2 oil), with a 30 PPM low NOx rating and a gross output of 11,716,000 Btu/hr.

The listing says the unit has been refurbished and fitted with new, updated controls, including an Allen-Bradley PowerFlex 400 variable frequency drive on the combustion air blower and a Hawk touchscreen burner control interface. Gas input runs from 1,429,000 to 14,288,000 Btu/hr, and oil input from 12.8 to 102.1 GPH. It is a UL listed gas-fired boiler assembly. This is our closest match if you searched for a Cleaver Brooks refurbished boiler.

2002 Cleaver Brooks CB200 (CBLE), rebuilt and never returned to service

A Cleaver Brooks CB200 in CBLE configuration (yard tag BSCB250HP271), located in Ohio. The listing states the system was completely rebuilt and never put back into service. It is a 250 HP low pressure packaged steam boiler, 15 PSI maximum allowable working pressure, serial number L-99065, dated 8/07/02, built by the Cleaver Brooks Division of Aqua-Chem in Milwaukee.

Nameplate input is 12,767,817 Btu/hr. It is dual fuel capable (natural gas or oil), with emission reduction equipment (Model AN52212), a 10 HP blower motor, and an oil pump motor. Main power is 460 volt, 3 phase, 60 Hz, with a 120 volt control circuit. Because it is rated 15 PSI, it fits heating and other low pressure steam loads, not high pressure process steam.

Cleaver Brooks CBEX-2W-700-500-150, new/unused

A Cleaver Brooks CBEX-2W-700-500-150 (stock BPSDM302006290), located in Ohio, listed as new/unused. It is a 500 HP packaged firetube steam boiler, natural gas fired, 150 PSI design pressure with a 100 PSIG operating pressure, and a 30 ppm NOx rating. Power is 460 volt, 3 phase, 60 Hz, and the customer site gas pressure on the data sheet is 5 psig. The description lists a 2022 date of manufacture, while the spec table shows 2019, so confirm the date on the nameplate.

Cleaver Brooks CB-500-200C mobile steam plant, like new

A Cleaver Brooks CB-500-200C (yard tag BSCB200HP282), located in Ohio, listed in used, like new condition. It is a complete 200 HP mobile steam plant inside a 40-foot insulated trailer, and the trailer is included. The boiler is 150 PSI design pressure and dual fuel, natural gas or No. 2 oil, with a maximum gas input of 8,370,000 Btu/hr and a 60.0 GPH maximum oil flow. It was converted and commissioned by Watco Ltée of Montreal, Quebec, and has Servitech burner management controls with mercury-free water level controls.

2011 Wellons biomass steam plant, new surplus

A 2011 Wellons 450 kW biomass cogeneration plant (yard tag B300HPBWSW450PSI049), located in Canandaigua, New York. It has two 300 HP, 450 PSI wood-chip fired steam boilers, model HCV.WF.300.VH.W, each rated 10,000 lb/hr on the nameplate. The listing describes it as new surplus with about 800 operating hours. The package includes an Elliott steam turbine, a Marathon MagnaMax generator, a Wellons electrostatic precipitator, the biomass feed system, a reverse osmosis feedwater system, and control panels.

Most of our inventory is good used equipment rather than refurbished. If a used unit fits your load better, see used Cleaver Brooks 150 HP boilers, used Cleaver Brooks 100 HP boilers, or all used boilers for sale.

What to check before you buy a refurbished boiler

A refurbished boiler is only worth the premium if the work is real and documented. Inspect it in person, or have a qualified inspector do it, and match every claim to the nameplate and the records.

FAQ

Is a refurbished boiler better than a used one?

Not automatically. A refurbished boiler is a used boiler with some work done. It is better only if that work addressed the parts that matter to you and is documented. A well-kept used boiler with good inspection records can be the smarter buy.

Do you sell refurbished Cleaver Brooks boilers?

Yes. Right now we list a refurbished 2015 CBLE 200-350-150ST with new controls and a rebuilt CB200 that was never returned to service, plus a new/unused CBEX-2W-700-500-150. See all used Cleaver Brooks boilers.

Do you have a refurbished B&W or Unilux boiler?

We do not have a Babcock & Wilcox boiler listed right now. We do list a used 2010 Unilux 2F 100 HS, a 30 HP, 150 PSIG flexible watertube steam boiler in a 20-foot container, available for purchase or rental. It is listed as used, not refurbished. Call us with the make and size you need.

What does a clearance boiler mean?

Clearance is about price, not condition. It can mean new surplus, an older unit, or equipment a seller needs to move. Judge it on the same nameplate, records, and inspection as any other used boiler.

Is a new surplus boiler under warranty?

Do not assume it is. Ask the seller and the manufacturer in writing whether any warranty applies.

How do I get pricing?

Our listings are call for price. Call (305) 428-2777 or use our contact page, and tell us the steam load, pressure, fuel, voltage, and timing you need. If you have a boiler to sell, see we buy boilers. If you need steam right away, ask about boiler rentals.

Find the right refurbished or surplus boiler

Start with the refurbished CBLE 200-350-150ST or browse all used boilers for sale. For a quote, help with sizing, or inspection and freight, contact us or call (305) 428-2777. We serve plants nationwide from Miami, Florida.