Used Cleaver Brooks CB700-150 150 HP Boilers
If you searched 700-150, 700 150, 700+150, or 700/150, you were looking for a Cleaver Brooks model number, not a price or a spare part. Those spellings all point to the same packaged firetube boiler: a 150 horsepower unit in fuel series 700, sold as a CB700-150 or, in the low-emission line, a CBLE-700-150. Longer tags such as 700-150-150ST or 700+150+150 usually add the design pressure and service, most often 150 psig steam.
Boilers.com buys and sells used commercial and industrial boilers and ships nationwide from Miami, Florida. Here is a plain reading of the 700-150 number, the published ratings, the used units we have listed, and what to inspect before you buy.
What the 700-150 model number means
Cleaver-Brooks builds the Model CB and CBLE model number from three main parts, each separated by a dash.
- CB or CBLE is the product family. CB is the standard packaged firetube. CBLE is the low-emission (LE) version of that family. The LE design uses induced flue gas recirculation to lower nitrogen oxide (NOx) emissions.
- 700 is the fuel series. It tells you which fuels the burner was built to fire. Series 700 is gas only as it left the factory. Other common series are 100 (No. 2 light oil only), 200 (No. 2 oil or gas), 400 (No. 6 heavy oil or gas), and 600 (No. 6 heavy oil only).
- 150 is the boiler horsepower. It is not automatically the design pressure.
A longer nameplate such as CBLE-700-150-150ST adds two more facts: 150 psig design pressure and ST for steam service. That is why some searches look like 700+150+150. A 700-150 can also be built for a different pressure. One used unit in our inventory, a CB-I-700-150LE, is rated 200 PSI steam. Read the nameplate before you treat “150” as 150 PSI.
The CBLE is a packaged firetube. The pressure vessel, integral forced-draft burner, burner controls, fan, damper, refractory, and trim are built as one unit. Cleaver-Brooks offers it as a four-pass dryback or waterback design, with five square feet of fireside heating surface per boiler horsepower.
Typical specifications for a CBLE 700-150
The figures below are Cleaver-Brooks published CBLE ratings for a 150 HP steam boiler, at sea level to 700 feet, from and at 212°F. A used boiler’s nameplate is the authority for that specific unit.
| Item | Rating |
|---|---|
| Manufacturer | Cleaver-Brooks |
| Common model numbers | CB700-150, CBLE-700-150, CBLE-700-150-150ST |
| Type | Packaged four-pass firetube |
| Boiler horsepower | 150 HP |
| Rated steam capacity | 5,175 lbs/hr from and at 212°F |
| Rated output | 5,021,000 Btu/hr |
| Typical gas input at rated capacity | About 6,123,000 to 6,124,000 Btu/hr |
| Fireside heating surface | 750 sq ft |
| Waterside heating surface | 820 sq ft |
| Factory fuel, series 700 | Natural gas only |
| Service | Steam or hot water (most used 700-150 units we list are steam) |
| Design pressure | Read the nameplate. 150ST means 150 psig steam. |
One boiler horsepower is the equivalent evaporation of 34.5 pounds of water per hour from and at 212°F, or 33,475 Btu/hr. That is why a 150 HP boiler is rated 5,175 lbs/hr (150 × 34.5) and about 5,021,000 Btu/hr.
Used 700-150 boilers in stock
We currently list more than one used Cleaver Brooks 700-150. Inventory changes, so start with our used Cleaver Brooks 150 HP boilers page or call us.
A featured unit is a used 2011 Cleaver-Brooks CBLE-700-150-150ST (yard tag BSCB150HP2662). It is a 150 HP firetube steam boiler with 150 PSI design pressure, fired on natural gas. The nameplate input is 6,124,000 Btu/hr. Steam output is about 5,175 lbs/hr, which matches the published CBLE rating. It has the integral CBLE low-emission burner, a gas manifold pressure of 2.8 in. W.C., and a stack economizer installed on the outlet.
Two other 700-150 variants are also listed:
- A 1997 CB-I-700-150LE, 150 HP, 200 PSI steam, natural gas, with 750 sq ft of heating surface and National Board No. 2643.
- A 1988 CB700-150, 150 HP, 150 PSI steam. It left the factory as a gas-fired series 700 boiler and has since been converted to No. 2 oil. It is housed in a containerized boiler room.
If you need dual fuel rather than a factory gas-only 700 series, we also list a 1992 CB-200-150 150 HP firetube. That model is fuel series 200 (natural gas or No. 2 oil), not a 700-150.
For other series 700 sizes, browse our used Cleaver Brooks boilers and used boilers inventory, including an 80 HP CB 700-80 and a 200 HP CB700-200-200.
Typical uses for a Cleaver Brooks 150 HP firetube
A 150 HP firetube is a mid-size packaged steam boiler. Cleaver-Brooks describes firetube service as supplying energy for heat, manufacturing processes, laundry, and kitchen service. Low-pressure steam (15 psig design) is typically used for heating. High-pressure steam is typically used for process loads. The large water volume in a firetube helps the boiler absorb load changes with less swing in steam pressure. This size is common on the used market for commercial, institutional, and mid-size manufacturing plants.
What to check when buying a used CB700-150
A firetube that has been maintained and fed treated water can run for decades. The risk is buying from photos alone. Inspect the boiler in person, or have a qualified inspector do it, and match every claim to the nameplate and the records.
- Nameplate and model number. Confirm the manufacturer, model (CB or CBLE, fuel series, horsepower, pressure, and ST or HW), serial number, year, fuel, and input. For a series 700 boiler, the factory fuel is gas only. If the listing says oil, ask what was converted and how.
- ASME and National Board identification. Look for a legible ASME nameplate and a National Board number. Insurers and jurisdictions usually want this paperwork, plus inspection, repair, and alteration records.
- Tubes, tube sheets, furnace, and doors. Open the front and rear doors and look at the fireside for soot, leakage, erosion, overheating, and prior tube work. Ask when, if ever, the boiler was retubed. On the waterside, look for scale, sludge, and corrosion. Check refractory and door seals. Cracked refractory and leaking seals are repair items, not cosmetic ones. Poor feedwater treatment is a common reason firetubes fail early.
- Burner, fan, and controls. Confirm the burner still matches the fuel you plan to burn. On a CBLE, the low-emission system and the combustion air fan are part of the same package. Ask whether the flame safeguard, low-water cutoff, and safety relief valves have been maintained or replaced. Safety valves deserve special attention.
- Emissions. A CBLE was built to a NOx target. Cleaver-Brooks has offered CBLE packages at 60, 30, 9, and down to less than 5 ppm NOx on natural gas, depending on the option. Used listings often omit the exact rating. If your plant has a permit limit, get the unit’s documented NOx level before you buy.
- Accessories, testing, and a walk-around. Some units, including our 2011 CBLE-700-150-150ST, include a stack economizer. Confirm whether feedwater equipment, a gas train, or a containerized room is included. Ask about recent hydrostatic tests and control checks, and look for overheating, corrosion, and erosion on the vessel. Do not rely on a datasheet and a few photographs.
We can help arrange an inspection. On our current 2011 CBLE listing, the buyer is responsible for removal, transport, and rigging, so confirm freight and rigging in the quote if you need delivery.
FAQ
What does 700-150 mean on a Cleaver Brooks boiler?
It is a model number. 700 is the gas-only fuel series. 150 is 150 boiler horsepower. People write it as 700-150, 700 150, 700+150, or 700/150. The low-emission model is a CBLE-700-150.
How much steam does a Cleaver Brooks 150 HP boiler make?
The published rating is 5,175 pounds per hour from and at 212°F, which is the standard 34.5 lbs/hr per boiler horsepower. Actual output in your plant depends on feedwater temperature, operating pressure, fuel, and the condition of the boiler.
What is the difference between a CB700-150 and a CBLE-700-150?
Both are 150 HP packaged firetubes in fuel series 700. CBLE is the low-emission version of the Model CB. It uses induced flue gas recirculation to reduce NOx. If you have an emissions limit, start with a CBLE, and still get the unit’s documented NOx rating.
Can a 700-150 burn oil?
As built, series 700 is gas only. Other series cover oil or dual fuel. Some used gas units have been converted, including a 1988 CB700-150 in our inventory that now runs on No. 2 oil. Treat a conversion as something to verify, not as a factory feature.
Is every 700-150 a 150 PSI steam boiler?
No. The 150 after 700 is horsepower. 150 psig steam is written as 150ST on many nameplates, and that is a common configuration, but we also have a 700-150 rated at 200 PSI. Always read the design pressure on the nameplate.
How do I get pricing or schedule a look at a unit?
Call 305-428-2777 or use our contact page. Tell us the pressure, fuel, steam or hot water, and timing you need. We will confirm what is in stock, send specs and availability, and help with inspection and nationwide shipping.
Look at a used CB700-150, or tell us what you need
If a used Cleaver Brooks 150 HP firetube is the right size, start with the 2011 CBLE-700-150-150ST or browse all used Cleaver Brooks 150 HP boilers. For a quote, questions about a conversion, or help matching a 700-150 to your plant, contact us or call 305-428-2777. We serve plants nationwide from Miami, Florida.