{"product_id":"sussman-ssb180-electric-steam-boiler-180-kw-240v-3-phase-asme-national-board-serial-n8-17576-t2001","title":"Sussman SSB180 Electric Steam Boiler - 180 kW, 240V 3-Phase, ASME, National Board (Serial# N8-17576-T2001)","description":"\u003cdiv class=\"show-info__description\"\u003e\n\u003cdiv class=\"show-info__section-text ql-editor p-0 overflow-hidden show-info__section-text--full\"\u003e\n\u003cp\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSussman Electric Steam Boiler, Model SSB180, Serial# N8-17576-T2001, Approximate 180kw, 3\/60\/240V, with tank \u0026amp; condensate return. Sussman Model SSB180 electric steam boiler removed from operating facility. This commercial-grade steam generator features 180 kW electric input capacity. ASME Code Section IV certified pressure vessel built to 100 PSIG maximum allowable working pressure, factory trimmed for 100 PSIG operating pressure. 240V 3-phase 433 amp power supply with 120VAC control voltage. UL Listed construction with National Board registration #49359. Manufactured by Sussman-Automatic Corporation in Long Island City, New York. Complete system includes boiler, condensate return tank (CS002), and integrated controls with \"TWO POWER SOURCES\" configuration. Ideal for hospitals, laundries, food processing, pharmaceutical manufacturing, commercial buildings, institutional facilities, or any application requiring clean electric steam without combustion emissions or gas piping.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEQUIPMENT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Sussman-Automatic Corporation\u003c\/li\u003e\n\u003cli\u003eModel Number: SSB180\u003c\/li\u003e\n\u003cli\u003eSerial Number: N8-17576-T2001\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA (Long Island City, New York)\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 49359\u003c\/li\u003e\n\u003cli\u003eConfiguration: Two Power Sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKilowatt Input: 180 kW\u003c\/li\u003e\n\u003cli\u003eMaximum Allowable Working Pressure: 100 PSIG\u003c\/li\u003e\n\u003cli\u003eOperating Pressure (Boiler Trimmed At): 100 PSIG\u003c\/li\u003e\n\u003cli\u003eASME Code: Section IV (Low Pressure Heating Boilers)\u003c\/li\u003e\n\u003cli\u003ePressure Vessel Construction: ASME Code M stamped\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Voltage: 240 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli\u003ePower Amperage: 433 Amps\u003c\/li\u003e\n\u003cli\u003eControl Voltage: 120 VAC\u003c\/li\u003e\n\u003cli\u003eControl Amperage: 15 Amps\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: Hardwired\u003c\/li\u003e\n\u003cli\u003eConfiguration: Two power sources\/circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertification \u0026amp; Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASME Code: Section IV (Code M)\u003c\/li\u003e\n\u003cli\u003eNational Board Registration: Yes (NB# 49359)\u003c\/li\u003e\n\u003cli\u003eUL Listed: Yes (Electric Boiler 3500)\u003c\/li\u003e\n\u003cli\u003eManufacturer: Sussman-Automatic Corporation\u003c\/li\u003e\n\u003cli\u003eMade in the USA: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Equipment:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSussman SSB180 electric steam boiler\u003c\/li\u003e\n\u003cli\u003eCondensate return tank (CS002)\u003c\/li\u003e\n\u003cli\u003eIntegrated control panel with indicators\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eHigh pressure cutoff protection\u003c\/li\u003e\n\u003cli\u003eElement cutout switches\u003c\/li\u003e\n\u003cli\u003eAuto\/Off\/Hand control selector\u003c\/li\u003e\n\u003cli\u003eBlowdown pilot light indicator\u003c\/li\u003e\n\u003cli\u003eTimer control (marked \"NOT IN USE\")\u003c\/li\u003e\n\u003cli\u003eAlarm system\u003c\/li\u003e\n\u003cli\u003eSafety interlocks\u003c\/li\u003e\n\u003cli\u003ePressure gauges\u003c\/li\u003e\n\u003cli\u003eTemperature controls\u003c\/li\u003e\n\u003cli\u003eFeedwater pump and connections\u003c\/li\u003e\n\u003cli\u003eSteam outlet connections\u003c\/li\u003e\n\u003cli\u003ePiping and valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControl Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFront-mounted control panel\u003c\/li\u003e\n\u003cli\u003eAuto\/Off\/Hand selector switch\u003c\/li\u003e\n\u003cli\u003eBlowdown pilot light\u003c\/li\u003e\n\u003cli\u003eTimer control\u003c\/li\u003e\n\u003cli\u003eTwo power sources configuration\u003c\/li\u003e\n\u003cli\u003eHoneywell controls\u003c\/li\u003e\n\u003cli\u003eWarning placard: \"DO NOT ADJUST THE CLEAN STEAM GENERATOR PRESSURE - THESE PRESSURE SETPOINTS ARE NOT TO BE ADJUSTED UNLESS MANUFACTURING MANAGEMENT IS ADVISED\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectric Steam Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZero emissions - no combustion products\u003c\/li\u003e\n\u003cli\u003eNo gas piping or fuel storage required\u003c\/li\u003e\n\u003cli\u003eNo flue or chimney requirements\u003c\/li\u003e\n\u003cli\u003eQuiet operation without burner noise\u003c\/li\u003e\n\u003cli\u003eQuick startup and response time\u003c\/li\u003e\n\u003cli\u003ePrecise steam pressure control\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance vs. fuel-fired\u003c\/li\u003e\n\u003cli\u003eClean steam for food\/pharmaceutical applications\u003c\/li\u003e\n\u003cli\u003eNearly 100% efficient energy conversion\u003c\/li\u003e\n\u003cli\u003eSuitable for locations without gas service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSussman Quality Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASME Code Section IV certified design\u003c\/li\u003e\n\u003cli\u003eNational Board registered and stamped\u003c\/li\u003e\n\u003cli\u003eUL Listed for safety compliance\u003c\/li\u003e\n\u003cli\u003eCompact vertical footprint\u003c\/li\u003e\n\u003cli\u003eMultiple immersion heating elements\u003c\/li\u003e\n\u003cli\u003eIntegrated electrical controls\u003c\/li\u003e\n\u003cli\u003eProfessional commercial-grade construction\u003c\/li\u003e\n\u003cli\u003eBuilt in USA (Long Island City, NY)\u003c\/li\u003e\n\u003cli\u003eTwo power sources for redundancy\/staging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e180 kW efficient electric heating\u003c\/li\u003e\n\u003cli\u003e100 PSIG operating pressure\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial\/institutional applications\u003c\/li\u003e\n\u003cli\u003eRapid steam generation\u003c\/li\u003e\n\u003cli\u003eMinimal installation requirements\u003c\/li\u003e\n\u003cli\u003eLow maintenance operation\u003c\/li\u003e\n\u003cli\u003eClean room compatible\u003c\/li\u003e\n\u003cli\u003eNo combustion air requirements\u003c\/li\u003e\n\u003cli\u003eIntegrated condensate return system\u003c\/li\u003e\n\u003cli\u003eDual power source configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComplete System Package:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler and condensate tank included\u003c\/li\u003e\n\u003cli\u003eAll controls and safeties installed\u003c\/li\u003e\n\u003cli\u003eReady for connection to steam distribution\u003c\/li\u003e\n\u003cli\u003eIntegrated feedwater pump system\u003c\/li\u003e\n\u003cli\u003eFactory-coordinated components\u003c\/li\u003e\n\u003cli\u003eSingle-source system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS SUMMARY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel: Sussman SSB180\u003c\/li\u003e\n\u003cli\u003eSerial: N8-17576-T2001\u003c\/li\u003e\n\u003cli\u003eInput: 180 kW electric\u003c\/li\u003e\n\u003cli\u003eMAWP: 100 PSIG\u003c\/li\u003e\n\u003cli\u003eOperating: 100 PSIG\u003c\/li\u003e\n\u003cli\u003eASME: Section IV (Code M)\u003c\/li\u003e\n\u003cli\u003eNB#: 49359\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary: 240V\/3-Phase\/50-60Hz\u003c\/li\u003e\n\u003cli\u003eAmperage: 433 Amps\u003c\/li\u003e\n\u003cli\u003eControl: 120 VAC, 15 Amps\u003c\/li\u003e\n\u003cli\u003eConfiguration: Two power sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaterial: Steel pressure vessel\u003c\/li\u003e\n\u003cli\u003eType: Vertical electric\u003c\/li\u003e\n\u003cli\u003eMounting: Floor\u003c\/li\u003e\n\u003cli\u003eCabinet: Blue powder-coated steel\u003c\/li\u003e\n\u003cli\u003eCertification: ASME, UL, National Board\u003c\/li\u003e\n\u003cli\u003eOrigin: USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectric steam boiler\u003c\/li\u003e\n\u003cli\u003eCondensate return tank (CS002)\u003c\/li\u003e\n\u003cli\u003eIntegrated control panel\u003c\/li\u003e\n\u003cli\u003eFeedwater pump\u003c\/li\u003e\n\u003cli\u003eSafety controls and interlocks\u003c\/li\u003e\n\u003cli\u003ePressure and temperature gauges\u003c\/li\u003e\n\u003cli\u003eFeedwater connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eADDITIONAL INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Used - Operating Facility Removal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Sussman-Automatic Corporation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation:\u003c\/strong\u003e Long Island City, New York USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SSB180\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Number:\u003c\/strong\u003e N8-17576-T2001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKilowatt Input:\u003c\/strong\u003e 180 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure:\u003c\/strong\u003e 100 PSIG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 100 PSIG (factory trimmed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 240V, 3-Phase, 50\/60 Hz, 433 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 120 VAC, 15 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASME Code:\u003c\/strong\u003e Section IV (Code M)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNational Board Number:\u003c\/strong\u003e 49359\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ASME, UL Listed (3500), National Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Finish:\u003c\/strong\u003e Blue powder-coated steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Vertical electric steam generator with two power sources\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIncluded:\u003c\/strong\u003e Boiler, condensate tank, feedwater pump, controls\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstimated Weight:\u003c\/strong\u003e 1,000-1,500 lbs (boiler and tank combined)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":46358972924044,"sku":"BSS180KW255","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-sussman-ssb-180-electric-steam-boiler-180-k-w-240-v-3-phase-asme-national-board-serial-n8.jpg?v=1771856107","url":"https:\/\/boilers.com\/products\/sussman-ssb180-electric-steam-boiler-180-kw-240v-3-phase-asme-national-board-serial-n8-17576-t2001","provider":"Boilers.com","version":"1.0","type":"link"}