{"product_id":"sussman-ssb135-electric-steam-boiler-144-kw-480v-3-phase-500-lb-hr-asme-stainless-steel-2015","title":"Sussman SSB135 Electric Steam Boiler - 144 kW, 480V 3-Phase, 500 lb\/hr, ASME, Stainless Steel (2015)","description":"\u003cdiv class=\"show-info__description\"\u003e\n\u003cdiv class=\"show-info__section-text ql-editor p-0 overflow-hidden show-info__section-text--full\"\u003e\n\u003cp\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSussman Stainless Steel Electric Steam Boiler, Model SSB135, Serial# N8-21242-W15, National Board# 152094, Year 2015. Approximate 144kw, 3\/60\/480V. Sussman SSB135 stainless steel electric steam boiler removed from operating facility. This compact commercial-grade steam generator features 144 kW electric input capacity producing 500 lb\/hr maximum steam output. ASME Code Section IV certified pressure vessel built to 100 PSIG maximum allowable working pressure, factory trimmed for 25 PSIG operating pressure. 480V 3-phase 173 amp power supply with 120VAC control voltage. UL Listed construction with National Board registration \u003ccode\u003e#152094\u003c\/code\u003e. Manufactured 2015 by Sussman-Automatic Corporation in Long Island City, New York. Ideal for hospitals, laundries, food processing, pharmaceutical manufacturing, commercial buildings, institutional facilities, or any application requiring clean electric steam without combustion emissions or gas piping.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEQUIPMENT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Sussman-Automatic Corporation\u003c\/li\u003e\n\u003cli\u003eModel Number: SSB135\u003c\/li\u003e\n\u003cli\u003eSerial Number: N8-21242-W15\u003c\/li\u003e\n\u003cli\u003eYear Built: 2015\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA (Long Island City, New York)\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 152094\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Capacity: 500 lb\/hr steam\u003c\/li\u003e\n\u003cli\u003eKilowatt Input: 144 kW\u003c\/li\u003e\n\u003cli\u003eMaximum Allowable Working Pressure: 100 PSIG\u003c\/li\u003e\n\u003cli\u003eOperating Pressure (Boiler Trimmed At): 25 PSIG\u003c\/li\u003e\n\u003cli\u003eASME Code: Section IV (Low Pressure Heating Boilers)\u003c\/li\u003e\n\u003cli\u003ePressure Vessel Construction: ASME stamped\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower Voltage: 480 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli\u003ePower Amperage: 173 Amps\u003c\/li\u003e\n\u003cli\u003eControl Voltage: 120 VAC\u003c\/li\u003e\n\u003cli\u003eControl Amperage: 15 Amps\u003c\/li\u003e\n\u003cli\u003eElectrical Connection: Hardwired\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertification \u0026amp; Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASME Code: Section IV\u003c\/li\u003e\n\u003cli\u003eNational Board Registration: Yes (NB# 152094)\u003c\/li\u003e\n\u003cli\u003eUL Listed: Yes (Electric Boiler)\u003c\/li\u003e\n\u003cli\u003eManufacturer: Sussman-Automatic Corporation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCabinet Material: Stainless steel construction\u003c\/li\u003e\n\u003cli\u003eMounting: Floor-mounted vertical design\u003c\/li\u003e\n\u003cli\u003eConfiguration: Compact electric steam generator\u003c\/li\u003e\n\u003cli\u003eElement Configuration: Multiple immersion heating elements\u003c\/li\u003e\n\u003cli\u003eFuse Protection: Multiple fuses visible in control panel\u003c\/li\u003e\n\u003cli\u003eControl Panel: Integrated front-mounted controls\u003c\/li\u003e\n\u003cli\u003eEstimated Weight: 800-1,200 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectric Steam Advantages:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZero emissions - no combustion products\u003c\/li\u003e\n\u003cli\u003eNo gas piping or fuel storage required\u003c\/li\u003e\n\u003cli\u003eNo flue or chimney requirements\u003c\/li\u003e\n\u003cli\u003eQuiet operation without burner noise\u003c\/li\u003e\n\u003cli\u003eQuick startup and response time\u003c\/li\u003e\n\u003cli\u003ePrecise steam pressure control\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance vs. fuel-fired\u003c\/li\u003e\n\u003cli\u003eClean steam for food\/pharmaceutical applications\u003c\/li\u003e\n\u003cli\u003eNearly 100% efficient energy conversion\u003c\/li\u003e\n\u003cli\u003eSuitable for locations without gas service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSussman Quality Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStainless steel pressure vessel construction\u003c\/li\u003e\n\u003cli\u003eASME Code Section IV certified design\u003c\/li\u003e\n\u003cli\u003eNational Board registered and stamped\u003c\/li\u003e\n\u003cli\u003eUL Listed for safety compliance\u003c\/li\u003e\n\u003cli\u003eCompact vertical footprint\u003c\/li\u003e\n\u003cli\u003eMultiple immersion heating elements\u003c\/li\u003e\n\u003cli\u003eIntegrated electrical controls\u003c\/li\u003e\n\u003cli\u003eProfessional commercial-grade construction\u003c\/li\u003e\n\u003cli\u003eBuilt in USA (Long Island City, NY)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e500 lb\/hr steam capacity\u003c\/li\u003e\n\u003cli\u003e144 kW efficient electric heating\u003c\/li\u003e\n\u003cli\u003e25 PSIG operating pressure (100 PSIG MAWP)\u003c\/li\u003e\n\u003cli\u003eSuitable for commercial\/institutional applications\u003c\/li\u003e\n\u003cli\u003eRapid steam generation\u003c\/li\u003e\n\u003cli\u003eMinimal installation requirements\u003c\/li\u003e\n\u003cli\u003eLow maintenance operation\u003c\/li\u003e\n\u003cli\u003eClean room compatible\u003c\/li\u003e\n\u003cli\u003eNo combustion air requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS SUMMARY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel: Sussman SSB135\u003c\/li\u003e\n\u003cli\u003eSerial: N8-21242-W15\u003c\/li\u003e\n\u003cli\u003eYear: 2015\u003c\/li\u003e\n\u003cli\u003eCapacity: 500 lb\/hr steam\u003c\/li\u003e\n\u003cli\u003eInput: 144 kW electric\u003c\/li\u003e\n\u003cli\u003eMAWP: 100 PSIG\u003c\/li\u003e\n\u003cli\u003eOperating: 25 PSIG\u003c\/li\u003e\n\u003cli\u003eASME: Section IV\u003c\/li\u003e\n\u003cli\u003eNB#: 152094\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary: 480V\/3-Phase\/50-60Hz\u003c\/li\u003e\n\u003cli\u003eAmperage: 173 Amps\u003c\/li\u003e\n\u003cli\u003eControl: 120 VAC, 15 Amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaterial: Stainless steel\u003c\/li\u003e\n\u003cli\u003eType: Vertical electric\u003c\/li\u003e\n\u003cli\u003eMounting: Floor\u003c\/li\u003e\n\u003cli\u003eCertification: ASME, UL, National Board\u003c\/li\u003e\n\u003cli\u003eOrigin: USA\u003c\/li\u003e\n\u003cli\u003eWeight: 800-1,200 lbs (est.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eADDITIONAL INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Used - 2015 Manufacture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Sussman-Automatic Corporation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation:\u003c\/strong\u003e Long Island City, New York USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SSB135\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Number:\u003c\/strong\u003e N8-21242-W15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear Built:\u003c\/strong\u003e 2015\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam Capacity:\u003c\/strong\u003e 500 lb\/hr maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKilowatt Input:\u003c\/strong\u003e 144 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure:\u003c\/strong\u003e 100 PSIG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressure:\u003c\/strong\u003e 25 PSIG (factory trimmed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 480V, 3-Phase, 50\/60 Hz, 173 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 120 VAC, 15 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eASME Code:\u003c\/strong\u003e Section IV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNational Board Number:\u003c\/strong\u003e 152094\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e ASME, UL Listed, National Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction Material:\u003c\/strong\u003e Stainless Steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Vertical electric steam generator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstimated Weight:\u003c\/strong\u003e 800-1,200 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEQUIPMENT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Sussman-Automatic Corporation\u003c\/li\u003e\n\u003cli\u003eModel Number: SSB135\u003c\/li\u003e\n\u003cli\u003eSerial Number: N8-21242-W15\u003c\/li\u003e\n\u003cli\u003eYear Built: 2015\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA (Long Island City, New York)\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 152094\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Capacity: 500 lb\/hr steam\u003c\/li\u003e\n\u003cli\u003eKilowatt Input: 144 kW\u003c\/li\u003e\n\u003cli\u003eMaximum Allowable Working Pressure: 100 PSIG\u003c\/li\u003e\n\u003cli\u003eOperating Pressure (Boiler Trimmed At): 25 PSIG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":46360454660236,"sku":"BSS144KW252","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-sussman-ssb-135-electric-steam-boiler-144-k-w-480-v-3-phase-500-lb-hr-asme-stainless-steel.jpg?v=1771859287","url":"https:\/\/boilers.com\/products\/sussman-ssb135-electric-steam-boiler-144-kw-480v-3-phase-500-lb-hr-asme-stainless-steel-2015","provider":"Boilers.com","version":"1.0","type":"link"}