{"product_id":"fulton-vsrt30-30hp-150psi-vertical-spiral-rib-tubeless-steam-boiler-2019","title":"Fulton VSRT30 30HP 150PSI Vertical Spiral Rib Tubeless Steam Boiler - 2019","description":"\u003cp\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFulton VSRT30 Vertical Spiral Rib Tubeless Steam Boiler - National Board Number 752, Serial Number F10110765A, Year Built 2019. Professional-grade natural gas-fired vertical spiral rib tubeless steam boiler featuring 1,005,000 BTU\/HR output capacity with 1,035 lbs\/hr steam generation at 150 PSI maximum allowable working pressure and 65 square feet heating surface. Complete packaged system includes Fulton integrated control panel, cyclone blower for combustion air, VFD drive control, and complete electrical systems. Built to ASME standards with innovative vertical spiral rib tubeless design for superior heat transfer and efficiency. Features 0.375\" shell thickness, 1.25\" head thickness, stainless steel construction, and modern digital monitoring systems. Maximum BTU input at altitude 1,200,000. Gas supply pressure range: 3\" WC minimum to 13.8\" WC maximum. Manifold gas pressure range: -2.8\" WC minimum to -3\" WC maximum. Complete with all safety trim and controls installed. Ideal for commercial buildings, light industrial facilities, institutional applications, or any operation requiring compact, efficient steam generation with proven Fulton vertical spiral rib tubeless technology and space-saving design.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEQUIPMENT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler Model Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Fulton\u003c\/li\u003e\n\u003cli\u003eLocation: Pulaski, NY USA 13142\u003c\/li\u003e\n\u003cli\u003eProduct Line: Vertical Spiral Rib Tubeless Boiler\u003c\/li\u003e\n\u003cli\u003eModel Number: VSRT 30\u003c\/li\u003e\n\u003cli\u003eSerial Number: F10110765A\u003c\/li\u003e\n\u003cli\u003eNational Board No: 752\u003c\/li\u003e\n\u003cli\u003eYear Built: 2019\u003c\/li\u003e\n\u003cli\u003eConfiguration: Vertical spiral rib tubeless steam boiler\u003c\/li\u003e\n\u003cli\u003eType: Natural gas-fired\u003c\/li\u003e\n\u003cli\u003eHorsepower: 30 HP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBTU Output: 1,005,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eHorsepower: 30 HP\u003c\/li\u003e\n\u003cli\u003eSteam Capacity: 1,035 lbs\/hr\u003c\/li\u003e\n\u003cli\u003eMaximum BTU Input at Altitude: 1,200,000\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 65 sq. ft.\u003c\/li\u003e\n\u003cli\u003eMaximum Allowable Working Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eShell Thickness: 0.375\" (3\/8\")\u003c\/li\u003e\n\u003cli\u003eHead Thickness: 1.25\"\u003c\/li\u003e\n\u003cli\u003eFuel Type: Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGas Supply Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas Supply Pressure Min: 3\" WC (Water Column)\u003c\/li\u003e\n\u003cli\u003eGas Supply Pressure Max: 13.8\" WC\u003c\/li\u003e\n\u003cli\u003eManifold Gas Pressure Min: -2.8\" WC\u003c\/li\u003e\n\u003cli\u003eManifold Gas Pressure Max: -3\" WC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler Electrical Rating: 240V, 60 Hz, 1-Phase, 30 FLA\u003c\/li\u003e\n\u003cli\u003eBurner Motor Rating: 240V, 50 Hz, 3-Phase, 9.6 Amps\u003c\/li\u003e\n\u003cli\u003eVFD Rating: 240V, 60 Hz, 1-Phase, 24 Amps\u003c\/li\u003e\n\u003cli\u003eWater Pump Motor Rating: 120V, 60 Hz, 1-Phase, 24 Amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration: Vertical\u003c\/li\u003e\n\u003cli\u003eDesign: Spiral rib tubeless\u003c\/li\u003e\n\u003cli\u003eConstruction: Stainless steel\u003c\/li\u003e\n\u003cli\u003eMounting: Floor-mounted\u003c\/li\u003e\n\u003cli\u003eFinish: Stainless steel exterior\u003c\/li\u003e\n\u003cli\u003eOrigin: USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFulton Quality Manufacturing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePremium USA boiler manufacturer\u003c\/li\u003e\n\u003cli\u003e2019 year of manufacture\u003c\/li\u003e\n\u003cli\u003eVertical Spiral Rib Tubeless series\u003c\/li\u003e\n\u003cli\u003eNational Board certified (752)\u003c\/li\u003e\n\u003cli\u003eHeavy-duty commercial construction\u003c\/li\u003e\n\u003cli\u003eProfessional installation quality\u003c\/li\u003e\n\u003cli\u003eNearly new condition\u003c\/li\u003e\n\u003cli\u003ePulaski, New York manufacturing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Efficiency Performance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 horsepower rating\u003c\/li\u003e\n\u003cli\u003e1,005,000 BTU\/HR output\u003c\/li\u003e\n\u003cli\u003e1,035 lbs\/hr steam generation\u003c\/li\u003e\n\u003cli\u003e65 sq. ft. heating surface\u003c\/li\u003e\n\u003cli\u003e150 PSI maximum working pressure\u003c\/li\u003e\n\u003cli\u003e1,200,000 BTU maximum input at altitude\u003c\/li\u003e\n\u003cli\u003eNatural gas fuel efficiency\u003c\/li\u003e\n\u003cli\u003eCompact vertical design\u003c\/li\u003e\n\u003cli\u003eContinuous duty rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Spiral Rib Tubeless Design:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInnovative spiral rib technology\u003c\/li\u003e\n\u003cli\u003eTubeless construction eliminates tube maintenance\u003c\/li\u003e\n\u003cli\u003eNo tube bundle to clean or replace\u003c\/li\u003e\n\u003cli\u003eVertical orientation saves floor space\u003c\/li\u003e\n\u003cli\u003eEnhanced heat transfer surfaces\u003c\/li\u003e\n\u003cli\u003eSpiral rib configuration maximizes efficiency\u003c\/li\u003e\n\u003cli\u003eFaster steam generation\u003c\/li\u003e\n\u003cli\u003eBetter thermal efficiency\u003c\/li\u003e\n\u003cli\u003eReduced maintenance requirements\u003c\/li\u003e\n\u003cli\u003eLonger service life\u003c\/li\u003e\n\u003cli\u003eImproved water circulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Combustion System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCyclone blower for combustion air\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive (VFD) control\u003c\/li\u003e\n\u003cli\u003eVFD rated 24 amps\u003c\/li\u003e\n\u003cli\u003eOptimized air\/fuel ratio\u003c\/li\u003e\n\u003cli\u003eEnhanced combustion efficiency\u003c\/li\u003e\n\u003cli\u003eReduced emissions\u003c\/li\u003e\n\u003cli\u003eProfessional burner management\u003c\/li\u003e\n\u003cli\u003eModern control technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Control Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton integrated control panel\u003c\/li\u003e\n\u003cli\u003eVFD drive control\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring\u003c\/li\u003e\n\u003cli\u003eDiagnostic capabilities\u003c\/li\u003e\n\u003cli\u003eTemperature and pressure monitoring\u003c\/li\u003e\n\u003cli\u003eUser-friendly operation\u003c\/li\u003e\n\u003cli\u003eWarning and alarm indicators\u003c\/li\u003e\n\u003cli\u003eProfessional-grade components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Construction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e0.375\" (3\/8\") shell thickness\u003c\/li\u003e\n\u003cli\u003e1.25\" head thickness\u003c\/li\u003e\n\u003cli\u003eStainless steel construction\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant materials\u003c\/li\u003e\n\u003cli\u003eRobust design\u003c\/li\u003e\n\u003cli\u003eLong service life\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNearly New Condition:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2019 year of manufacture\u003c\/li\u003e\n\u003cli\u003eModern design and technology\u003c\/li\u003e\n\u003cli\u003eRecent construction standards\u003c\/li\u003e\n\u003cli\u003eMinimal operating hours\u003c\/li\u003e\n\u003cli\u003eExcellent condition\u003c\/li\u003e\n\u003cli\u003eCurrent safety standards\u003c\/li\u003e\n\u003cli\u003eUp-to-date engineering\u003c\/li\u003e\n\u003cli\u003eExtended service life remaining\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e150 PSI ASME design pressure\u003c\/li\u003e\n\u003cli\u003eNational Board certified (752)\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003cli\u003eSafety relief valve protection\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eCode-compliant installation\u003c\/li\u003e\n\u003cli\u003eProfessional engineering\u003c\/li\u003e\n\u003cli\u003eETL certified to UL STD 795 and CSA STD 3.1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSYSTEM COMPONENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Boiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Model VSRT 30\u003c\/li\u003e\n\u003cli\u003eSerial Number F10110765A\u003c\/li\u003e\n\u003cli\u003eNational Board No: 752\u003c\/li\u003e\n\u003cli\u003eYear 2019 manufacture\u003c\/li\u003e\n\u003cli\u003eVertical spiral rib tubeless design\u003c\/li\u003e\n\u003cli\u003e30 HP capacity\u003c\/li\u003e\n\u003cli\u003e65 sq. ft. heating surface\u003c\/li\u003e\n\u003cli\u003e150 PSI MAWP\u003c\/li\u003e\n\u003cli\u003eStainless steel construction\u003c\/li\u003e\n\u003cli\u003eComplete with all trim\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBurner System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas burner\u003c\/li\u003e\n\u003cli\u003ePower burner design\u003c\/li\u003e\n\u003cli\u003eForced draft combustion\u003c\/li\u003e\n\u003cli\u003eModulating control capability\u003c\/li\u003e\n\u003cli\u003eGas train components\u003c\/li\u003e\n\u003cli\u003eSafety shut-off valves\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eProfessional installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCombustion Air System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCyclone blower assembly\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive control\u003c\/li\u003e\n\u003cli\u003eVFD rated 24 amps\u003c\/li\u003e\n\u003cli\u003eAir damper controls\u003c\/li\u003e\n\u003cli\u003eCombustion air ducting\u003c\/li\u003e\n\u003cli\u003eProfessional installation\u003c\/li\u003e\n\u003cli\u003eOptimized air delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControl Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton integrated control panel\u003c\/li\u003e\n\u003cli\u003eVFD drive control panel\u003c\/li\u003e\n\u003cli\u003eBurner management system\u003c\/li\u003e\n\u003cli\u003eFlame safeguard controls\u003c\/li\u003e\n\u003cli\u003eOperational diagnostics\u003c\/li\u003e\n\u003cli\u003eTemperature controls\u003c\/li\u003e\n\u003cli\u003ePressure monitoring\u003c\/li\u003e\n\u003cli\u003eSafety interlocks\u003c\/li\u003e\n\u003cli\u003eWarning and alarm indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e240V single-phase power supply\u003c\/li\u003e\n\u003cli\u003e60 Hz frequency\u003c\/li\u003e\n\u003cli\u003e30 FLA boiler rating\u003c\/li\u003e\n\u003cli\u003eBurner motor: 240V, 50 Hz, 3-Ph, 9.6A\u003c\/li\u003e\n\u003cli\u003eVFD: 240V, 60 Hz, 1-Ph, 24A\u003c\/li\u003e\n\u003cli\u003eWater pump: 120V, 60 Hz, 1-Ph, 24A\u003c\/li\u003e\n\u003cli\u003eAll wiring and connections\u003c\/li\u003e\n\u003cli\u003eDisconnect provisions\u003c\/li\u003e\n\u003cli\u003eCircuit protection\u003c\/li\u003e\n\u003cli\u003eProfessional installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Instrumentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003ePressure gauge\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eWater level controls\u003c\/li\u003e\n\u003cli\u003eGas pressure switches\u003c\/li\u003e\n\u003cli\u003eFlame supervision\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003eSemi-annual handhole inspection label\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWater System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeedwater pump (120V, 24A)\u003c\/li\u003e\n\u003cli\u003eWater level controls\u003c\/li\u003e\n\u003cli\u003eFeedwater valves\u003c\/li\u003e\n\u003cli\u003ePiping connections\u003c\/li\u003e\n\u003cli\u003eBlowdown valve\u003c\/li\u003e\n\u003cli\u003eDrain connections\u003c\/li\u003e\n\u003cli\u003eLevel indication\u003c\/li\u003e\n\u003cli\u003eLow water protection\u003c\/li\u003e\n\u003cli\u003eHandhole access ports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGas System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGas pressure regulator\u003c\/li\u003e\n\u003cli\u003eManual gas valve\u003c\/li\u003e\n\u003cli\u003eSafety shut-off valves\u003c\/li\u003e\n\u003cli\u003eGas pressure switches\u003c\/li\u003e\n\u003cli\u003eInlet connection\u003c\/li\u003e\n\u003cli\u003eManifold pressure monitoring\u003c\/li\u003e\n\u003cli\u003eSafety interlocks\u003c\/li\u003e\n\u003cli\u003eProfessional gas train\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS SUMMARY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Fulton\u003c\/li\u003e\n\u003cli\u003eLocation: Pulaski, NY USA 13142\u003c\/li\u003e\n\u003cli\u003eModel: VSRT 30\u003c\/li\u003e\n\u003cli\u003eSerial No: F10110765A\u003c\/li\u003e\n\u003cli\u003eNational Board: 752\u003c\/li\u003e\n\u003cli\u003eYear: 2019\u003c\/li\u003e\n\u003cli\u003eType: Vertical spiral rib tubeless steam boiler\u003c\/li\u003e\n\u003cli\u003eFuel: Natural Gas\u003c\/li\u003e\n\u003cli\u003eHorsepower: 30 HP\u003c\/li\u003e\n\u003cli\u003eOutput: 1,005,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eMax Input: 1,200,000 BTU at altitude\u003c\/li\u003e\n\u003cli\u003eSteam: 1,035 lbs\/hr\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 65 sq. ft.\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eShell: 0.375\" thickness\u003c\/li\u003e\n\u003cli\u003eHead: 1.25\" thickness\u003c\/li\u003e\n\u003cli\u003eOrigin: USA\u003c\/li\u003e\n\u003cli\u003eConstruction: Stainless steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGas Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply Pressure Min: 3\" WC\u003c\/li\u003e\n\u003cli\u003eSupply Pressure Max: 13.8\" WC\u003c\/li\u003e\n\u003cli\u003eManifold Pressure Min: -2.8\" WC\u003c\/li\u003e\n\u003cli\u003eManifold Pressure Max: -3\" WC\u003c\/li\u003e\n\u003cli\u003eFuel Type: Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler: 240V, 1-Ph, 60 Hz, 30 FLA\u003c\/li\u003e\n\u003cli\u003eBurner Motor: 240V, 3-Ph, 50 Hz, 9.6A\u003c\/li\u003e\n\u003cli\u003eVFD: 240V, 1-Ph, 60 Hz, 24A\u003c\/li\u003e\n\u003cli\u003eWater Pump: 120V, 1-Ph, 60 Hz, 24A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eETL Certified to UL STD 795\u003c\/li\u003e\n\u003cli\u003eCertified to CSA STD 3.1\u003c\/li\u003e\n\u003cli\u003eNational Board Certified (752)\u003c\/li\u003e\n\u003cli\u003eASME \"S\" Stamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfiguration: Vertical\u003c\/li\u003e\n\u003cli\u003eDesign: Spiral rib tubeless\u003c\/li\u003e\n\u003cli\u003eMounting: Floor-mounted\u003c\/li\u003e\n\u003cli\u003eFinish: Stainless steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eADDITIONAL INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Used - 2019 Manufacture, Excellent Condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Fulton Steam Solutions, Inc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Location:\u003c\/strong\u003e Pulaski, NY USA 13142\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Vertical Spiral Rib Tubeless Boiler\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e VSRT 30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Number:\u003c\/strong\u003e F10110765A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNational Board Number:\u003c\/strong\u003e 752\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear Built:\u003c\/strong\u003e 2019\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type:\u003c\/strong\u003e Natural Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBTU Output:\u003c\/strong\u003e 1,005,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum BTU Input at Altitude:\u003c\/strong\u003e 1,200,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower:\u003c\/strong\u003e 30 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam Generation:\u003c\/strong\u003e 1,035 lbs\/hr\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Surface:\u003c\/strong\u003e 65 square feet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure:\u003c\/strong\u003e 150 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShell Thickness:\u003c\/strong\u003e 0.375 inches (3\/8\")\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHead Thickness:\u003c\/strong\u003e 1.25 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Supply Pressure:\u003c\/strong\u003e 3\" WC minimum to 13.8\" WC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManifold Gas Pressure:\u003c\/strong\u003e -2.8\" WC minimum to -3\" WC maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler: 240V, 1-Phase, 60 Hz, 30 FLA\u003c\/li\u003e\n\u003cli\u003eBurner Motor: 240V, 3-Phase, 50 Hz, 9.6 Amps\u003c\/li\u003e\n\u003cli\u003eVFD: 240V, 1-Phase, 60 Hz, 24 Amps\u003c\/li\u003e\n\u003cli\u003eWater Pump Motor: 120V, 1-Phase, 60 Hz, 24 Amps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eETL Certified to UL STD 795\u003c\/li\u003e\n\u003cli\u003eCertified to CSA STD 3.1\u003c\/li\u003e\n\u003cli\u003eASME \"S\" Stamp on Shell\u003c\/li\u003e\n\u003cli\u003eNational Board Certification (752)\u003c\/li\u003e\n\u003cli\u003eIntertek Listing (4001483)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControl System:\u003c\/strong\u003e Fulton integrated control panel with VFD drive\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCombustion Air System:\u003c\/strong\u003e Cyclone blower with VFD control\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eFlame supervision system\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003ePressure relief protection\u003c\/li\u003e\n\u003cli\u003eGas pressure monitoring\u003c\/li\u003e\n\u003cli\u003eProfessional safety controls\u003c\/li\u003e\n\u003cli\u003eSemi-annual handhole inspection requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 inches clearance at top\u003c\/li\u003e\n\u003cli\u003e36 inches clearance at front\u003c\/li\u003e\n\u003cli\u003e18 inches at sides, rear and from flue pipe\u003c\/li\u003e\n\u003cli\u003eFloor beneath unit shall be noncombustible\u003c\/li\u003e\n\u003cli\u003eProfessional installation required\u003c\/li\u003e\n\u003cli\u003eFoundation specifications per manufacturer\u003c\/li\u003e\n\u003cli\u003eAdequate clearances per code requirements\u003c\/li\u003e\n\u003cli\u003eProfessional rigging and placement\u003c\/li\u003e\n\u003cli\u003eElectrical hookup by licensed electrician\u003c\/li\u003e\n\u003cli\u003eGas connection by licensed professional\u003c\/li\u003e\n\u003cli\u003eProfessional commissioning recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Vertical Spiral Rib Tubeless Boiler design\u003c\/li\u003e\n\u003cli\u003e2019 year of manufacture - nearly new condition\u003c\/li\u003e\n\u003cli\u003e30 horsepower rating\u003c\/li\u003e\n\u003cli\u003e1,005,000 BTU\/HR output capacity\u003c\/li\u003e\n\u003cli\u003e1,200,000 BTU maximum input at altitude\u003c\/li\u003e\n\u003cli\u003e1,035 lbs\/hr steam generation\u003c\/li\u003e\n\u003cli\u003e65 square feet heating surface\u003c\/li\u003e\n\u003cli\u003e150 PSI maximum working pressure\u003c\/li\u003e\n\u003cli\u003eNatural gas-fired for efficient operation\u003c\/li\u003e\n\u003cli\u003eVertical spiral rib tubeless design\u003c\/li\u003e\n\u003cli\u003eNo tube bundle to clean or replace\u003c\/li\u003e\n\u003cli\u003eSpiral rib configuration maximizes heat transfer\u003c\/li\u003e\n\u003cli\u003eTubeless construction eliminates tube maintenance\u003c\/li\u003e\n\u003cli\u003eCompact vertical footprint saves floor space\u003c\/li\u003e\n\u003cli\u003eHeavy-duty 0.375\" shell thickness\u003c\/li\u003e\n\u003cli\u003eRobust 1.25\" head thickness\u003c\/li\u003e\n\u003cli\u003eStainless steel construction for corrosion resistance\u003c\/li\u003e\n\u003cli\u003eNational Board certified (752)\u003c\/li\u003e\n\u003cli\u003eASME construction and certification\u003c\/li\u003e\n\u003cli\u003eETL certified to UL STD 795 and CSA STD 3.1\u003c\/li\u003e\n\u003cli\u003eCyclone blower for combustion air\u003c\/li\u003e\n\u003cli\u003eVariable frequency drive (VFD) control\u003c\/li\u003e\n\u003cli\u003eVFD rated 24 amps\u003c\/li\u003e\n\u003cli\u003eFulton integrated control system\u003c\/li\u003e\n\u003cli\u003eReal-time monitoring and diagnostics\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve protection\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eAll safety trim and controls installed\u003c\/li\u003e\n\u003cli\u003eComplete electrical package\u003c\/li\u003e\n\u003cli\u003eBurner motor: 240V, 3-Phase, 9.6A\u003c\/li\u003e\n\u003cli\u003eWater pump: 120V, 1-Phase, 24A\u003c\/li\u003e\n\u003cli\u003eProfessional-grade components throughout\u003c\/li\u003e\n\u003cli\u003eComplete packaged system\u003c\/li\u003e\n\u003cli\u003eSemi-annual handhole inspection access\u003c\/li\u003e\n\u003cli\u003eSpecial tee handle wrench available from factory\u003c\/li\u003e\n\u003cli\u003eReady for natural gas connection and startup\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2019 manufacture - excellent condition\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eETL certified to UL and CSA standards\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eProfessional-grade commercial\/industrial construction\u003c\/li\u003e\n\u003cli\u003ePulaski, New York USA manufacturing quality\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":46262143287436,"sku":"BSF30HP270","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-fulton-vsrt-30-30-hp-150-psi-vertical-spiral-rib-tubeless-steam-boiler-2019.jpg?v=1770729884","url":"https:\/\/boilers.com\/products\/fulton-vsrt30-30hp-150psi-vertical-spiral-rib-tubeless-steam-boiler-2019","provider":"Boilers.com","version":"1.0","type":"link"}