{"product_id":"fulton-50hp-150psi-classic-vertical-tubeless-steam-boiler-model-fb-050-a-natural-gas-2017","title":"Fulton 50HP 150PSI Classic Vertical Tubeless Steam Boiler - Model FB-050-A - Natural Gas - 2017","description":"\u003cp\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFulton Classic Vertical Tubeless Steam Boiler - Model FB-050-A, Boiler Number PV-459-PP, National Board Number 123435, Year Built 2017. Professional-grade natural gas-fired vertical tubeless steam boiler featuring 1,674,000 BTU\/HR output capacity with 1,725 lbs\/hr steam output at 150 PSI maximum allowable working pressure. Complete system with 150 square feet of heating surface, 5\/16-inch shell thickness, 5\/8-inch head thickness, and 230V three-phase electrical package rated at 12 FLA. Built to ASME standards for natural gas operation with gas supply pressure requirements of 7–13.8 in WC. Burner motor rated 230V, 3-phase, 6 amps with water pump motor rated 230V, 3-phase, 2.2 amps.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis sale includes the complete boiler system package: Fulton Classic FB-050-A boiler, Fulton VT60 Condensate Return System (Serial 20260, Order 539005), blowdown tank, Pulsatron chemical metering pump, and H-O-H Water Technology NanoTron Dual Timer Controller (Model NANO-F2). Complete integrated steam system ready for installation. Heavy-duty commercial construction ideal for commercial laundries, food processing, breweries, institutional facilities, manufacturing operations, or any facility requiring reliable mid-range natural gas steam generation with proven Fulton Classic reliability and efficient gas-fired operation.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eEQUIPMENT SPECIFICATIONS\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler Model Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Fulton Boiler Works, Inc.\u003c\/li\u003e\n\u003cli\u003eLocation: Pulaski, New York, USA 13142\u003c\/li\u003e\n\u003cli\u003eProduct Line: Classic Vertical Tubeless Steam Boiler\u003c\/li\u003e\n\u003cli\u003eBoiler Number: PV-459-PP\u003c\/li\u003e\n\u003cli\u003eModel Number: FB-050-A\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 123435\u003c\/li\u003e\n\u003cli\u003eYear Built: 2017\u003c\/li\u003e\n\u003cli\u003eConfiguration: Vertical tubeless steam boiler\u003c\/li\u003e\n\u003cli\u003eType: Natural gas-fired\u003c\/li\u003e\n\u003cli\u003eSteam Output: 1,725 lbs\/hr\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBTU Output: 1,674,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eMax BTU Input at Altitude (0–1,999 ft): 2,093,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eSteam Output: 1,725 lbs\/hr\u003c\/li\u003e\n\u003cli\u003eMaximum Allowable Working Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 150 sq ft\u003c\/li\u003e\n\u003cli\u003eShell Thickness: 5\/16 in\u003c\/li\u003e\n\u003cli\u003eHead Thickness: 5\/8 in\u003c\/li\u003e\n\u003cli\u003eFuel Type: Natural Gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGas Supply Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuel: Natural Gas\u003c\/li\u003e\n\u003cli\u003eGas Supply Pressure: Min 7 in WC \/ Max 13.8 in WC\u003c\/li\u003e\n\u003cli\u003eManifold Gas Pressure: Min 0.7 in WC \/ Max 4.8 in WC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler Electrical Rating: 230V, 3-Phase, 60 Hz, 12 FLA\u003c\/li\u003e\n\u003cli\u003eBurner Motor Rating: 230V, 3-Phase, 60 Hz, 6 Amps\u003c\/li\u003e\n\u003cli\u003eWater Pump Motor Rating: 230V, 3-Phase, 60 Hz, 2.2 Amps\u003c\/li\u003e\n\u003cli\u003eWater Treatment Controller: H-O-H NANO-F2, 100–240 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Vessel (ASME Drum Plate):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified By: FBW (Fulton Boiler Works)\u003c\/li\u003e\n\u003cli\u003eNational Board Serial Number: 123463\u003c\/li\u003e\n\u003cli\u003eManufacturer's Serial Number: U-2760\u003c\/li\u003e\n\u003cli\u003eModel: F-50\u003c\/li\u003e\n\u003cli\u003eYear Built: 2017\u003c\/li\u003e\n\u003cli\u003eMAWP: 75 PSI at 400°F\u003c\/li\u003e\n\u003cli\u003eMin Design Metal Temperature: 50°F at 75 PSI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFulton Classic Quality Manufacturing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePremium USA boiler manufacturer\u003c\/li\u003e\n\u003cli\u003e2017 year of manufacture\u003c\/li\u003e\n\u003cli\u003eClassic Vertical Tubeless Steam Boiler series\u003c\/li\u003e\n\u003cli\u003eHeavy-duty commercial\/industrial construction\u003c\/li\u003e\n\u003cli\u003eProfessional engineering and design\u003c\/li\u003e\n\u003cli\u003eProven reliability in demanding applications\u003c\/li\u003e\n\u003cli\u003ePulaski, New York manufacturing quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Performance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1,725 lbs\/hr steam output\u003c\/li\u003e\n\u003cli\u003e1,674,000 BTU\/HR output rating\u003c\/li\u003e\n\u003cli\u003e2,093,000 BTU\/HR max input at altitude\u003c\/li\u003e\n\u003cli\u003e150 PSI maximum working pressure\u003c\/li\u003e\n\u003cli\u003e150 sq ft heating surface\u003c\/li\u003e\n\u003cli\u003eContinuous duty rated\u003c\/li\u003e\n\u003cli\u003eCommercial\/industrial grade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNatural Gas Operation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas-fired burner system\u003c\/li\u003e\n\u003cli\u003eGas supply pressure: 7–13.8 in WC\u003c\/li\u003e\n\u003cli\u003eManifold gas pressure: 0.7–4.8 in WC\u003c\/li\u003e\n\u003cli\u003eReliable clean-burning gas performance\u003c\/li\u003e\n\u003cli\u003eConsistent combustion\u003c\/li\u003e\n\u003cli\u003eProfessional gas train\u003c\/li\u003e\n\u003cli\u003eOptimized combustion system\u003c\/li\u003e\n\u003cli\u003eCommercial gas burner design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVertical Tubeless Design:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Classic proven design\u003c\/li\u003e\n\u003cli\u003eCompact installation footprint\u003c\/li\u003e\n\u003cli\u003eNo tube sheets or tube bundles\u003c\/li\u003e\n\u003cli\u003eReduced maintenance complexity\u003c\/li\u003e\n\u003cli\u003eLarge water volume for consistent steam\u003c\/li\u003e\n\u003cli\u003e150 sq ft heating surface\u003c\/li\u003e\n\u003cli\u003e5\/16-inch shell \/ 5\/8-inch head construction\u003c\/li\u003e\n\u003cli\u003eFactory-tested components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Steam System Package:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Classic FB-050-A boiler included\u003c\/li\u003e\n\u003cli\u003eFulton VT60 Condensate Return System included\u003c\/li\u003e\n\u003cli\u003eBlowdown tank included\u003c\/li\u003e\n\u003cli\u003ePulsatron chemical metering pump included\u003c\/li\u003e\n\u003cli\u003eH-O-H NanoTron NANO-F2 dual timer controller included\u003c\/li\u003e\n\u003cli\u003eComplete integrated system — ready for installation\u003c\/li\u003e\n\u003cli\u003eReduces sourcing time and cost vs. assembling components separately\u003c\/li\u003e\n\u003cli\u003eAll components factory-matched to boiler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater Treatment System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eH-O-H Water Technology NanoTron NANO-F2 controller\u003c\/li\u003e\n\u003cli\u003eDual timer control automation\u003c\/li\u003e\n\u003cli\u003ePulsatron chemical metering pump\u003c\/li\u003e\n\u003cli\u003ePrecise automated chemical dosing\u003c\/li\u003e\n\u003cli\u003eProtects pressure vessel from scale and corrosion\u003c\/li\u003e\n\u003cli\u003eExtends boiler service life\u003c\/li\u003e\n\u003cli\u003eProfessional-grade water treatment solution\u003c\/li\u003e\n\u003cli\u003e100–240 VAC, 50\/60 Hz operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e230V three-phase boiler electrical rating\u003c\/li\u003e\n\u003cli\u003e12 FLA boiler electrical rating\u003c\/li\u003e\n\u003cli\u003e230V, 3-phase, 6-amp burner motor\u003c\/li\u003e\n\u003cli\u003e230V, 3-phase, 2.2-amp water pump motor\u003c\/li\u003e\n\u003cli\u003eH-O-H NANO-F2 water treatment controller\u003c\/li\u003e\n\u003cli\u003eProfessional electrical package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Construction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty pressure vessel design\u003c\/li\u003e\n\u003cli\u003eProven Fulton Classic engineering\u003c\/li\u003e\n\u003cli\u003eDurable steel construction — 5\/16-inch shell \/ 5\/8-inch head\u003c\/li\u003e\n\u003cli\u003eProfessional-grade components\u003c\/li\u003e\n\u003cli\u003eLong service life design\u003c\/li\u003e\n\u003cli\u003eASME-certified pressure vessel\u003c\/li\u003e\n\u003cli\u003eNational Board registered\u003c\/li\u003e\n\u003cli\u003eCommercial quality throughout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e150 PSI MAWP ASME steam boiler\u003c\/li\u003e\n\u003cli\u003eASME pressure vessel certification\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003eCode-compliant construction\u003c\/li\u003e\n\u003cli\u003eProfessional safety engineering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSYSTEM COMPONENTS\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Boiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Classic Model FB-050-A\u003c\/li\u003e\n\u003cli\u003eBoiler Number PV-459-PP\u003c\/li\u003e\n\u003cli\u003eNational Board Number 123435\u003c\/li\u003e\n\u003cli\u003eYear Built 2017\u003c\/li\u003e\n\u003cli\u003e1,725 lbs\/hr steam output\u003c\/li\u003e\n\u003cli\u003e1,674,000 BTU\/HR output capacity\u003c\/li\u003e\n\u003cli\u003e150 PSI MAWP\u003c\/li\u003e\n\u003cli\u003e150 sq ft heating surface\u003c\/li\u003e\n\u003cli\u003eNatural gas fired\u003c\/li\u003e\n\u003cli\u003eComplete with all trim and controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBurner System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas-fired burner assembly\u003c\/li\u003e\n\u003cli\u003eForced draft combustion\u003c\/li\u003e\n\u003cli\u003eGas train components\u003c\/li\u003e\n\u003cli\u003eSafety shut-off valves\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eGas pressure monitoring\u003c\/li\u003e\n\u003cli\u003eProfessional burner management\u003c\/li\u003e\n\u003cli\u003eBurner motor: 230V, 3PH, 60Hz, 6A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated control panel\u003c\/li\u003e\n\u003cli\u003eBurner management system\u003c\/li\u003e\n\u003cli\u003eFlame safeguard controls\u003c\/li\u003e\n\u003cli\u003eOperational diagnostics\u003c\/li\u003e\n\u003cli\u003eTemperature controls\u003c\/li\u003e\n\u003cli\u003ePressure monitoring\u003c\/li\u003e\n\u003cli\u003eSafety interlocks\u003c\/li\u003e\n\u003cli\u003eBoiler electrical: 230V, 3PH, 60Hz, 12 FLA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e230V, 3-phase, 60 Hz boiler electrical (12 FLA)\u003c\/li\u003e\n\u003cli\u003eBurner motor: 230V, 3PH, 60Hz, 6A\u003c\/li\u003e\n\u003cli\u003eWater pump motor: 230V, 3PH, 60Hz, 2.2A\u003c\/li\u003e\n\u003cli\u003eH-O-H NANO-F2 controller: 100–240 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eAll wiring and connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondensate Return System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Return System Model VT60\u003c\/li\u003e\n\u003cli\u003eSerial Number 20260\u003c\/li\u003e\n\u003cli\u003eOrder Number 539005\u003c\/li\u003e\n\u003cli\u003eCondensate collection and return\u003c\/li\u003e\n\u003cli\u003eFeedwater system integration\u003c\/li\u003e\n\u003cli\u003eFactory-matched to FB-050-A boiler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater Treatment System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eH-O-H Water Technology NanoTron Controller\u003c\/li\u003e\n\u003cli\u003eModel NANO-F2\u003c\/li\u003e\n\u003cli\u003eSerial Number 0310844E19-004\u003c\/li\u003e\n\u003cli\u003eDual timer control\u003c\/li\u003e\n\u003cli\u003e100–240 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePulsatron chemical metering pump\u003c\/li\u003e\n\u003cli\u003eAutomated chemical dosing program\u003c\/li\u003e\n\u003cli\u003eScale and corrosion protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBlowdown System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBlowdown tank included\u003c\/li\u003e\n\u003cli\u003eManual blowdown valves\u003c\/li\u003e\n\u003cli\u003eSafe blowdown water cooling\/separation\u003c\/li\u003e\n\u003cli\u003eProper blowdown management\u003c\/li\u003e\n\u003cli\u003eDrain connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Instrumentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eSteam pressure gauge\u003c\/li\u003e\n\u003cli\u003eWater level controls and indicators\u003c\/li\u003e\n\u003cli\u003eFlame supervision system\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003eASME pressure vessel certification\u003c\/li\u003e\n\u003cli\u003eNational Board registration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWater System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeedwater connections\u003c\/li\u003e\n\u003cli\u003eWater level controls\u003c\/li\u003e\n\u003cli\u003eBlowdown valves and tank\u003c\/li\u003e\n\u003cli\u003ePiping connections\u003c\/li\u003e\n\u003cli\u003eDrain connections\u003c\/li\u003e\n\u003cli\u003eLevel indication\u003c\/li\u003e\n\u003cli\u003eLow water protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSPECIFICATIONS SUMMARY\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Fulton Boiler Works, Inc.\u003c\/li\u003e\n\u003cli\u003eLocation: Pulaski, New York, USA\u003c\/li\u003e\n\u003cli\u003eModel: FB-050-A\u003c\/li\u003e\n\u003cli\u003eBoiler No.: PV-459-PP\u003c\/li\u003e\n\u003cli\u003eNational Board No.: 123435\u003c\/li\u003e\n\u003cli\u003eYear Built: 2017\u003c\/li\u003e\n\u003cli\u003eType: Classic Vertical Tubeless Steam Boiler\u003c\/li\u003e\n\u003cli\u003eFuel: Natural Gas\u003c\/li\u003e\n\u003cli\u003eBTU Output: 1,674,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eMax BTU Input: 2,093,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eSteam Output: 1,725 lbs\/hr\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 150 sq ft\u003c\/li\u003e\n\u003cli\u003eShell Thickness: 5\/16 in\u003c\/li\u003e\n\u003cli\u003eHead Thickness: 5\/8 in\u003c\/li\u003e\n\u003cli\u003eASME Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGas Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuel Type: Natural Gas\u003c\/li\u003e\n\u003cli\u003eGas Supply Pressure: Min 7 \/ Max 13.8 in WC\u003c\/li\u003e\n\u003cli\u003eManifold Gas Pressure: Min 0.7 \/ Max 4.8 in WC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler Rating: 230V, 3-Ph, 60 Hz, 12 FLA\u003c\/li\u003e\n\u003cli\u003eBurner Motor: 230V, 3-Ph, 60 Hz, 6A\u003c\/li\u003e\n\u003cli\u003eWater Pump Motor: 230V, 3-Ph, 60 Hz, 2.2A\u003c\/li\u003e\n\u003cli\u003eWater Treatment: 100–240 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackage Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler: Fulton FB-050-A, NB# 123435\u003c\/li\u003e\n\u003cli\u003eReturn System: Fulton VT60, S\/N 20260\u003c\/li\u003e\n\u003cli\u003eBlowdown Tank: Included\u003c\/li\u003e\n\u003cli\u003eChemical Pump: Pulsatron Metering Pump\u003c\/li\u003e\n\u003cli\u003eWater Treatment Controller: H-O-H NANO-F2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eADDITIONAL INFORMATION\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Used — 2017 Manufacture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Fulton Boiler Works, Inc., Pulaski, New York, USA 13142\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Classic Vertical Tubeless Steam Boiler\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e FB-050-A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBoiler Number:\u003c\/strong\u003e PV-459-PP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNational Board Number:\u003c\/strong\u003e 123435\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear Built:\u003c\/strong\u003e 2017\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type:\u003c\/strong\u003e Natural Gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBTU Output:\u003c\/strong\u003e 1,674,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteam Output:\u003c\/strong\u003e 1,725 lbs\/hr\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure:\u003c\/strong\u003e 150 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating Surface:\u003c\/strong\u003e 150 sq ft\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler Electrical Rating: 230V, 3-Phase, 60 Hz, 12 FLA\u003c\/li\u003e\n\u003cli\u003eBurner Motor Rating: 230V, 3-Phase, 60 Hz, 6 Amps\u003c\/li\u003e\n\u003cli\u003eWater Pump Motor Rating: 230V, 3-Phase, 60 Hz, 2.2 Amps\u003c\/li\u003e\n\u003cli\u003eWater Treatment Controller: 100–240 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl System:\u003c\/strong\u003e Integrated burner management and control panel\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBurner System:\u003c\/strong\u003e Natural gas-fired burner assembly\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eFlame supervision system\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003ePressure relief protection\u003c\/li\u003e\n\u003cli\u003eASME pressure vessel certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRequires natural gas supply connection (7–13.8 in WC)\u003c\/li\u003e\n\u003cli\u003e230V, 3-phase, 60 Hz electrical service required\u003c\/li\u003e\n\u003cli\u003eAll system components included for complete installation\u003c\/li\u003e\n\u003cli\u003eSite preparation and gas\/electrical connections required\u003c\/li\u003e\n\u003cli\u003eProfessional installation recommended\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFulton Classic vertical tubeless steam boiler design\u003c\/li\u003e\n\u003cli\u003e2017 year of manufacture\u003c\/li\u003e\n\u003cli\u003e1,725 lbs\/hr steam output capacity\u003c\/li\u003e\n\u003cli\u003e1,674,000 BTU\/HR output rating\u003c\/li\u003e\n\u003cli\u003e2,093,000 BTU\/HR max BTU input at altitude\u003c\/li\u003e\n\u003cli\u003e150 PSI maximum allowable working pressure\u003c\/li\u003e\n\u003cli\u003eNatural gas fired operation\u003c\/li\u003e\n\u003cli\u003eGas supply pressure: 7–13.8 in WC\u003c\/li\u003e\n\u003cli\u003eManifold gas pressure: 0.7–4.8 in WC\u003c\/li\u003e\n\u003cli\u003eASME construction and National Board certification\u003c\/li\u003e\n\u003cli\u003e150 sq ft heating surface\u003c\/li\u003e\n\u003cli\u003e5\/16-inch shell \/ 5\/8-inch head construction\u003c\/li\u003e\n\u003cli\u003e230V three-phase boiler electrical package (12 FLA)\u003c\/li\u003e\n\u003cli\u003eBurner motor: 230V, 3-phase, 6 amps\u003c\/li\u003e\n\u003cli\u003eWater pump motor: 230V, 3-phase, 2.2 amps\u003c\/li\u003e\n\u003cli\u003eComplete integrated steam system package\u003c\/li\u003e\n\u003cli\u003eFulton VT60 condensate return system included (S\/N 20260)\u003c\/li\u003e\n\u003cli\u003eBlowdown tank included\u003c\/li\u003e\n\u003cli\u003ePulsatron chemical metering pump included\u003c\/li\u003e\n\u003cli\u003eH-O-H NanoTron NANO-F2 dual timer water treatment controller included\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eProven Fulton Classic reliability\u003c\/li\u003e\n\u003cli\u003ePulaski, New York USA manufacturing\u003c\/li\u003e\n\u003cli\u003eReady for gas connection and startup\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":47689948823692,"sku":"BSF50HP278","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-fulton-50-hp-150-psi-classic-vertical-tubeless-steam-boiler-model-fb-050-a-natural-gas-201.jpg?v=1776675419","url":"https:\/\/boilers.com\/products\/fulton-50hp-150psi-classic-vertical-tubeless-steam-boiler-model-fb-050-a-natural-gas-2017","provider":"Boilers.com","version":"1.0","type":"link"}