{"product_id":"fes-gea-industrial-ammonia-screw-compressor-package-natural-refrigerant-r-717-2002","title":"FES \/ GEA Industrial Ammonia Screw Compressor Package Natural Refrigerant R-717 2002","description":"\u003cp\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFES Systems \/ GEA Industrial Ammonia Refrigeration Screw Compressor Package — FES Serial Number 020449, National Board Number 12955, Year 2002. Heavy-duty industrial ammonia (R-717) screw compressor package certified by FES Systems Inc. with 300 PSI maximum allowable working pressure at 500°F and minimum design metal temperature of 20°F at 300 PSI. Complete skid-mounted package with integrated GEA microprocessor control panel, oil separator vessel, suction accumulator, Henry Technologies Chil-Con liquid separator vessel (Model TSCC-08084-100, Serial C211050B-3, NB# 13643, Year 2001), drive motor, and all associated piping, valves, and instrumentation.\u003c\/p\u003e\n\u003cp\u003eComplete industrial ammonia refrigeration compressor package mounted on a heavy-duty structural steel skid with all pressure vessels, controls, and safety systems intact. Ammonia refrigerant (R-717) system with full integrated skid assembly. Heavy-duty industrial construction ideal for cold storage facilities, food processing plants, ice rinks, industrial refrigeration systems, pharmaceutical manufacturing, or any large-scale industrial application requiring proven ammonia refrigeration technology with GEA \/ FES screw compressor reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: This is an ammonia (R-717) refrigeration system. Buyer is responsible for proper ammonia handling, evacuation, and compliance with all applicable federal, state, and local regulations regarding ammonia refrigerant systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEQUIPMENT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompressor Package Identification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: FES Systems Inc. (GEA Refrigeration)\u003c\/li\u003e\n\u003cli\u003eProduct Line: Industrial Ammonia Screw Compressor Package\u003c\/li\u003e\n\u003cli\u003eRefrigerant: Ammonia (R-717)\u003c\/li\u003e\n\u003cli\u003eFES Serial Number: 020449\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 12955\u003c\/li\u003e\n\u003cli\u003eYear: 2002\u003c\/li\u003e\n\u003cli\u003eControl System: GEA Microprocessor Control Panel\u003c\/li\u003e\n\u003cli\u003eConfiguration: Skid-mounted package\u003c\/li\u003e\n\u003cli\u003eASME \/ National Board Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFES Systems Pressure Vessel (Oil Separator):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified By: FES Systems Inc.\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 12955\u003c\/li\u003e\n\u003cli\u003eFES Serial Number: 020449\u003c\/li\u003e\n\u003cli\u003eYear: 2002\u003c\/li\u003e\n\u003cli\u003eMAWP: 300 PSI at 500°F\u003c\/li\u003e\n\u003cli\u003eMDMT: 20°F at 300 PSI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHenry Technologies Vessel (Liquid Separator):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified By: Henry Technologies, Chil-Con Products\u003c\/li\u003e\n\u003cli\u003eManufacturing Location: Brantford, Ontario, Canada\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 13643\u003c\/li\u003e\n\u003cli\u003eModel: TSCC-08084-100\u003c\/li\u003e\n\u003cli\u003eSerial Number: C211050B-3\u003c\/li\u003e\n\u003cli\u003eDate: 2001\u003c\/li\u003e\n\u003cli\u003eCRN: L9753.256809\u003c\/li\u003e\n\u003cli\u003eMAWP: 400 PSI at 250°F \/ 300 PSI at 200°F\u003c\/li\u003e\n\u003cli\u003eMDMT: -20°F at 400 PSI \/ -20°F at 300 PSI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRefrigerant Type: Ammonia (R-717)\u003c\/li\u003e\n\u003cli\u003eSystem Type: Industrial ammonia refrigeration\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Screw compressor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFES Systems \/ GEA Quality Manufacturing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFES Systems Inc. — leading industrial ammonia compressor manufacturer\u003c\/li\u003e\n\u003cli\u003eGEA Refrigeration product lineage (FES acquired by GEA)\u003c\/li\u003e\n\u003cli\u003e2002 year of manufacture\u003c\/li\u003e\n\u003cli\u003eIndustrial ammonia screw compressor design\u003c\/li\u003e\n\u003cli\u003eHeavy-duty commercial\/industrial construction\u003c\/li\u003e\n\u003cli\u003eProfessional engineering and design\u003c\/li\u003e\n\u003cli\u003eProven reliability in demanding industrial refrigeration applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Ammonia Screw Compressor Design:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eScrew compressor technology for continuous-duty operation\u003c\/li\u003e\n\u003cli\u003eAmmonia (R-717) natural refrigerant — zero GWP, zero ODP\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency ammonia refrigeration cycle\u003c\/li\u003e\n\u003cli\u003eLarge-scale industrial refrigeration capacity\u003c\/li\u003e\n\u003cli\u003eRobust skid-mounted package design\u003c\/li\u003e\n\u003cli\u003eDesigned for 24\/7 continuous industrial service\u003c\/li\u003e\n\u003cli\u003eLong service life construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGEA Microprocessor Control System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated GEA microprocessor control panel\u003c\/li\u003e\n\u003cli\u003eKeypad operator interface\u003c\/li\u003e\n\u003cli\u003eDigital display and monitoring\u003c\/li\u003e\n\u003cli\u003eCompressor capacity control\u003c\/li\u003e\n\u003cli\u003eOperating parameter monitoring\u003c\/li\u003e\n\u003cli\u003eSafety interlock integration\u003c\/li\u003e\n\u003cli\u003eProfessional industrial controls package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eComplete Skid-Mounted Package:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull compressor package on heavy-duty structural steel skid\u003c\/li\u003e\n\u003cli\u003eAll pressure vessels included on skid\u003c\/li\u003e\n\u003cli\u003eIntegrated oil separator vessel (FES, NB# 12955)\u003c\/li\u003e\n\u003cli\u003eHenry Technologies liquid separator vessel included (NB# 13643)\u003c\/li\u003e\n\u003cli\u003eDrive motor included\u003c\/li\u003e\n\u003cli\u003eOil system components included\u003c\/li\u003e\n\u003cli\u003eAll skid piping, valves, and instrumentation\u003c\/li\u003e\n\u003cli\u003eFactory-assembled and integrated package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmmonia (R-717) Natural Refrigerant:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural refrigerant — no phase-out concerns\u003c\/li\u003e\n\u003cli\u003eZero global warming potential (GWP)\u003c\/li\u003e\n\u003cli\u003eZero ozone depletion potential (ODP)\u003c\/li\u003e\n\u003cli\u003eHigh thermodynamic efficiency\u003c\/li\u003e\n\u003cli\u003eIndustry standard for industrial refrigeration\u003c\/li\u003e\n\u003cli\u003eLong-term refrigerant supply assured\u003c\/li\u003e\n\u003cli\u003eNo refrigerant replacement cost risk\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eASME Certified Pressure Vessels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFES Systems pressure vessel — ASME certified, NB# 12955\u003c\/li\u003e\n\u003cli\u003eHenry Technologies vessel — ASME certified, NB# 13643\u003c\/li\u003e\n\u003cli\u003eNational Board registered vessels\u003c\/li\u003e\n\u003cli\u003e300 PSI rated FES vessel\u003c\/li\u003e\n\u003cli\u003e400 PSI rated Henry Technologies vessel\u003c\/li\u003e\n\u003cli\u003eProfessional pressure vessel construction\u003c\/li\u003e\n\u003cli\u003eCode-compliant design and certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASME-certified pressure vessel construction\u003c\/li\u003e\n\u003cli\u003eNational Board registered vessels\u003c\/li\u003e\n\u003cli\u003e300 PSI MAWP FES oil separator\u003c\/li\u003e\n\u003cli\u003e400 PSI MAWP Henry Technologies vessel\u003c\/li\u003e\n\u003cli\u003eSafety relief valve provisions\u003c\/li\u003e\n\u003cli\u003eAmmonia safety compliance design\u003c\/li\u003e\n\u003cli\u003eProfessional industrial safety systems\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSYSTEM COMPONENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Compressor:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial ammonia screw compressor\u003c\/li\u003e\n\u003cli\u003eFES Systems \/ GEA design\u003c\/li\u003e\n\u003cli\u003eSkid-mounted configuration\u003c\/li\u003e\n\u003cli\u003eDrive motor included\u003c\/li\u003e\n\u003cli\u003eCompressor capacity control system\u003c\/li\u003e\n\u003cli\u003eOil injection system\u003c\/li\u003e\n\u003cli\u003eSuction and discharge connections\u003c\/li\u003e\n\u003cli\u003eComplete compressor assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGEA Control Panel:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGEA microprocessor controller\u003c\/li\u003e\n\u003cli\u003eKeypad operator interface\u003c\/li\u003e\n\u003cli\u003eDigital display panel\u003c\/li\u003e\n\u003cli\u003eCapacity control functions\u003c\/li\u003e\n\u003cli\u003eSafety interlock integration\u003c\/li\u003e\n\u003cli\u003eOperational monitoring\u003c\/li\u003e\n\u003cli\u003eProfessional industrial controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFES Oil Separator Vessel:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified by FES Systems Inc.\u003c\/li\u003e\n\u003cli\u003eNational Board Number 12955\u003c\/li\u003e\n\u003cli\u003eFES Serial Number 020449\u003c\/li\u003e\n\u003cli\u003eYear 2002\u003c\/li\u003e\n\u003cli\u003eMAWP 300 PSI at 500°F\u003c\/li\u003e\n\u003cli\u003eMDMT 20°F at 300 PSI\u003c\/li\u003e\n\u003cli\u003eASME certified construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHenry Technologies Liquid Separator Vessel:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertified by Henry Technologies, Chil-Con Products\u003c\/li\u003e\n\u003cli\u003eNational Board Number 13643\u003c\/li\u003e\n\u003cli\u003eModel TSCC-08084-100\u003c\/li\u003e\n\u003cli\u003eSerial Number C211050B-3\u003c\/li\u003e\n\u003cli\u003eDate 2001\u003c\/li\u003e\n\u003cli\u003eCRN L9753.256809\u003c\/li\u003e\n\u003cli\u003eMAWP 400 PSI at 250°F \/ 300 PSI at 200°F\u003c\/li\u003e\n\u003cli\u003eMDMT -20°F at 400 and 300 PSI\u003c\/li\u003e\n\u003cli\u003eMade in Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOil System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil separator vessel (FES, NB# 12955)\u003c\/li\u003e\n\u003cli\u003eOil return system\u003c\/li\u003e\n\u003cli\u003eOil level controls\u003c\/li\u003e\n\u003cli\u003eOil filter provisions\u003c\/li\u003e\n\u003cli\u003eOil injection to compressor\u003c\/li\u003e\n\u003cli\u003eOil management instrumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSuction System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSuction accumulator \/ separator vessel\u003c\/li\u003e\n\u003cli\u003eSuction header piping\u003c\/li\u003e\n\u003cli\u003eSuction isolation valves\u003c\/li\u003e\n\u003cli\u003eSuction pressure monitoring\u003c\/li\u003e\n\u003cli\u003eLiquid carryover protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Instrumentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety relief valves\u003c\/li\u003e\n\u003cli\u003ePressure gauges\u003c\/li\u003e\n\u003cli\u003eHigh pressure safety cutouts\u003c\/li\u003e\n\u003cli\u003eLow pressure safety cutouts\u003c\/li\u003e\n\u003cli\u003eHigh temperature protection\u003c\/li\u003e\n\u003cli\u003eOil pressure safety\u003c\/li\u003e\n\u003cli\u003eAmmonia leak provisions\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStructural Assembly:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty structural steel skid base\u003c\/li\u003e\n\u003cli\u003eAll vessels mounted to skid\u003c\/li\u003e\n\u003cli\u003eIntegrated skid piping and valves\u003c\/li\u003e\n\u003cli\u003eProfessional industrial assembly\u003c\/li\u003e\n\u003cli\u003eForklift pocket provisions\u003c\/li\u003e\n\u003cli\u003eReady for rigging and relocation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS SUMMARY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompressor Package:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: FES Systems Inc. \/ GEA Refrigeration\u003c\/li\u003e\n\u003cli\u003eFES Serial Number: 020449\u003c\/li\u003e\n\u003cli\u003eNational Board Number: 12955\u003c\/li\u003e\n\u003cli\u003eYear: 2002\u003c\/li\u003e\n\u003cli\u003eRefrigerant: Ammonia (R-717)\u003c\/li\u003e\n\u003cli\u003eCompressor Type: Screw compressor\u003c\/li\u003e\n\u003cli\u003eControl System: GEA Microprocessor Panel\u003c\/li\u003e\n\u003cli\u003eConfiguration: Skid-mounted package\u003c\/li\u003e\n\u003cli\u003eASME Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFES Oil Separator Vessel:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNB#: 12955\u003c\/li\u003e\n\u003cli\u003eFES S\/N: 020449\u003c\/li\u003e\n\u003cli\u003eYear: 2002\u003c\/li\u003e\n\u003cli\u003eMAWP: 300 PSI at 500°F\u003c\/li\u003e\n\u003cli\u003eMDMT: 20°F at 300 PSI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHenry Technologies Liquid Separator:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNB#: 13643\u003c\/li\u003e\n\u003cli\u003eModel: TSCC-08084-100\u003c\/li\u003e\n\u003cli\u003eSerial: C211050B-3\u003c\/li\u003e\n\u003cli\u003eDate: 2001\u003c\/li\u003e\n\u003cli\u003eCRN: L9753.256809\u003c\/li\u003e\n\u003cli\u003eMAWP: 400 PSI at 250°F \/ 300 PSI at 200°F\u003c\/li\u003e\n\u003cli\u003eMDMT: -20°F at both ratings\u003c\/li\u003e\n\u003cli\u003eOrigin: Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eADDITIONAL INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Used — 2002 Manufacture, Previously Installed Industrial Refrigeration System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e FES Systems Inc. (GEA Refrigeration)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFES Serial Number:\u003c\/strong\u003e 020449\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNational Board Number:\u003c\/strong\u003e 12955\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYear:\u003c\/strong\u003e 2002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e Ammonia (R-717)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor Type:\u003c\/strong\u003e Industrial screw compressor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASME-certified pressure vessel construction\u003c\/li\u003e\n\u003cli\u003eNational Board registered vessels\u003c\/li\u003e\n\u003cli\u003eSafety relief valve provisions\u003c\/li\u003e\n\u003cli\u003eHigh and low pressure safety cutouts\u003c\/li\u003e\n\u003cli\u003eHigh temperature protection\u003c\/li\u003e\n\u003cli\u003eOil pressure safety interlocks\u003c\/li\u003e\n\u003cli\u003eMultiple operational safety interlocks\u003c\/li\u003e\n\u003cli\u003eAmmonia-rated design and construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete skid-mounted package — professional rigging required for removal\u003c\/li\u003e\n\u003cli\u003eAmmonia refrigerant system — requires licensed ammonia contractor for decommissioning\u003c\/li\u003e\n\u003cli\u003eBuyer responsible for ammonia evacuation and disposal per applicable regulations\u003c\/li\u003e\n\u003cli\u003eAll pressure vessels intact and included on skid\u003c\/li\u003e\n\u003cli\u003eProfessional rigging and crane service recommended\u003c\/li\u003e\n\u003cli\u003eSite inspection welcome prior to purchase\u003c\/li\u003e\n\u003cli\u003eCompressor HP and capacity data not available from nameplate — buyer to verify\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFES Systems \/ GEA industrial ammonia screw compressor package\u003c\/li\u003e\n\u003cli\u003e2002 year of manufacture\u003c\/li\u003e\n\u003cli\u003eAmmonia (R-717) natural refrigerant — zero GWP, zero ODP\u003c\/li\u003e\n\u003cli\u003eIndustrial screw compressor design for continuous-duty operation\u003c\/li\u003e\n\u003cli\u003eGEA microprocessor control panel with keypad interface\u003c\/li\u003e\n\u003cli\u003eASME-certified FES oil separator vessel — NB# 12955, 300 PSI MAWP\u003c\/li\u003e\n\u003cli\u003eHenry Technologies Chil-Con liquid separator — NB# 13643, 400 PSI MAWP\u003c\/li\u003e\n\u003cli\u003eHenry Technologies Model TSCC-08084-100, Serial C211050B-3, CRN L9753.256809\u003c\/li\u003e\n\u003cli\u003eComplete skid-mounted package — all vessels, motor, controls included\u003c\/li\u003e\n\u003cli\u003eHeavy-duty structural steel skid base\u003c\/li\u003e\n\u003cli\u003eOil separator and return system included\u003c\/li\u003e\n\u003cli\u003eSuction accumulator \/ liquid separator included\u003c\/li\u003e\n\u003cli\u003eAll skid piping, valves, and instrumentation included\u003c\/li\u003e\n\u003cli\u003eSafety relief valve provisions\u003c\/li\u003e\n\u003cli\u003eHigh and low pressure safety cutouts\u003c\/li\u003e\n\u003cli\u003eProven FES Systems \/ GEA industrial refrigeration reliability\u003c\/li\u003e\n\u003cli\u003eIdeal for cold storage, food processing, ice rinks, industrial refrigeration\u003c\/li\u003e\n\u003cli\u003ePreviously installed industrial refrigeration system\u003c\/li\u003e\n\u003cli\u003eProfessional rigging required for removal\u003c\/li\u003e\n\u003cli\u003eAmmonia contractor required for decommissioning\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":47689725149324,"sku":"CASFGNG280","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-fes-gea-industrial-ammonia-screw-compressor-package-natural-refrigerant-r-717-2002_9.jpg?v=1776666938","url":"https:\/\/boilers.com\/products\/fes-gea-industrial-ammonia-screw-compressor-package-natural-refrigerant-r-717-2002","provider":"Boilers.com","version":"1.0","type":"link"}