{"product_id":"cleaver-brooks-600hp-150psi-packaged-steam-boiler-cb-600-600","title":"Cleaver Brooks 600HP 150PSI Packaged Steam Boiler CB-600-600","description":"\u003cp\u003e\u003cstrong\u003eOVERVIEW\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE: This boiler was previously installed in a trailer configuration and has been removed for stationary installation. This sale includes the boiler only - no deaerator (DA) tank is included.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCleaver Brooks CB Packaged Boiler - Model CB-600-600, Serial Number L-66078, Date 1\/23\/79. Professional-grade oil-fired packaged steam boiler featuring 25,106,000 BTU\/HR input capacity with 600 horsepower rating at 150 PSI maximum allowable working pressure. Complete industrial packaged system with integrated control systems and 208V three-phase electrical package rated at 99 amps. Built to ASME standards for oil-fired operation with 167.5 GPH oil consumption rating. Minimum circuit ampacity 114 amps with maximum circuit protection rating of 396 amps. Previously housed in mobile trailer configuration, now available as standalone stationary unit. Complete boiler assembly with all trim and controls installed. Heavy-duty industrial construction ideal for large commercial facilities, industrial plants, institutional applications, manufacturing operations, or any facility requiring high-capacity steam generation with proven Cleaver Brooks reliability and efficient oil-fired operation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEQUIPMENT SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler Model Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Cleaver Brooks Division\u003c\/li\u003e\n\u003cli\u003eLocation: Aqua-Chem, Inc., Milwaukee, Wisconsin, USA\u003c\/li\u003e\n\u003cli\u003eProduct Line: CB Packaged Boiler\u003c\/li\u003e\n\u003cli\u003eModel Number: CB-600-600\u003c\/li\u003e\n\u003cli\u003eSerial Number: L-66078\u003c\/li\u003e\n\u003cli\u003eDate: 1\/23\/79\u003c\/li\u003e\n\u003cli\u003eConfiguration: Packaged steam boiler\u003c\/li\u003e\n\u003cli\u003eType: Oil-fired\u003c\/li\u003e\n\u003cli\u003eHorsepower Rating: 600 HP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBTU Input: 25,106,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eHorsepower: 600 HP\u003c\/li\u003e\n\u003cli\u003eMaximum Allowable Working Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eFuel Type: Oil\u003c\/li\u003e\n\u003cli\u003eOil Consumption: 167.5 GPH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Power Supply: 208V, 3-Phase, 60 Hz, 99 Amps\u003c\/li\u003e\n\u003cli\u003eMinimum Circuit Ampacity: 114 Amps\u003c\/li\u003e\n\u003cli\u003eMaximum Rating of Circuit Protection: 396 Amps\u003c\/li\u003e\n\u003cli\u003eControl Circuit: 120V, 1-Phase, 60 Hz, 7 Amps\u003c\/li\u003e\n\u003cli\u003eOil Pump Motor: 208V\u003c\/li\u003e\n\u003cli\u003eBlower Motor: Per specifications\u003c\/li\u003e\n\u003cli\u003eAir Compressor Motor: Per specifications\u003c\/li\u003e\n\u003cli\u003eOil Heater: KW rating per specifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFuel Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuel: Oil\u003c\/li\u003e\n\u003cli\u003eOil Consumption: 167.5 GPH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevious Installation: Mobile trailer-mounted\u003c\/li\u003e\n\u003cli\u003eCurrent Configuration: Standalone unit\u003c\/li\u003e\n\u003cli\u003eMounting: Skid-mounted for stationary installation\u003c\/li\u003e\n\u003cli\u003eOrigin: USA\u003c\/li\u003e\n\u003cli\u003eASME Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCleaver Brooks Quality Manufacturing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePremium USA boiler manufacturer\u003c\/li\u003e\n\u003cli\u003e1979 manufacture date\u003c\/li\u003e\n\u003cli\u003eCB Packaged Boiler series\u003c\/li\u003e\n\u003cli\u003eHeavy-duty commercial\/industrial construction\u003c\/li\u003e\n\u003cli\u003eProfessional engineering and design\u003c\/li\u003e\n\u003cli\u003eProven reliability in demanding applications\u003c\/li\u003e\n\u003cli\u003eMilwaukee, Wisconsin manufacturing quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Capacity Performance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 horsepower rating\u003c\/li\u003e\n\u003cli\u003e25,106,000 BTU\/HR input\u003c\/li\u003e\n\u003cli\u003e150 PSI maximum working pressure\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial capacity\u003c\/li\u003e\n\u003cli\u003eContinuous duty rated\u003c\/li\u003e\n\u003cli\u003eLarge-scale steam generation\u003c\/li\u003e\n\u003cli\u003eRobust packaged design\u003c\/li\u003e\n\u003cli\u003eCommercial\/industrial grade\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOil-Fired Operation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil-fired burner system\u003c\/li\u003e\n\u003cli\u003e167.5 GPH oil consumption rating\u003c\/li\u003e\n\u003cli\u003eReliable fuel oil performance\u003c\/li\u003e\n\u003cli\u003eHigh BTU content fuel\u003c\/li\u003e\n\u003cli\u003eConsistent combustion\u003c\/li\u003e\n\u003cli\u003eProfessional oil train\u003c\/li\u003e\n\u003cli\u003eOptimized combustion system\u003c\/li\u003e\n\u003cli\u003eIndustrial oil burner design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePackaged Boiler Design:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete factory-assembled package\u003c\/li\u003e\n\u003cli\u003eIntegrated burner and controls\u003c\/li\u003e\n\u003cli\u003ePre-wired electrical systems\u003c\/li\u003e\n\u003cli\u003eAll trim and controls installed\u003c\/li\u003e\n\u003cli\u003eSimplified installation\u003c\/li\u003e\n\u003cli\u003eReduced field labor requirements\u003c\/li\u003e\n\u003cli\u003eFactory-tested components\u003c\/li\u003e\n\u003cli\u003eProfessional assembly quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFormerly Trailer-Mounted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePreviously mobile configuration\u003c\/li\u003e\n\u003cli\u003eRemoved from trailer for stationary use\u003c\/li\u003e\n\u003cli\u003eMaintained structural integrity\u003c\/li\u003e\n\u003cli\u003eSkid-mounted for permanent installation\u003c\/li\u003e\n\u003cli\u003eProfessional dismounting\u003c\/li\u003e\n\u003cli\u003eReady for foundation mounting\u003c\/li\u003e\n\u003cli\u003eTransportable with appropriate equipment\u003c\/li\u003e\n\u003cli\u003eFlexible installation options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e208V three-phase power supply\u003c\/li\u003e\n\u003cli\u003e99 amp main power rating\u003c\/li\u003e\n\u003cli\u003e114 amp minimum circuit ampacity\u003c\/li\u003e\n\u003cli\u003e396 amp maximum circuit protection\u003c\/li\u003e\n\u003cli\u003e120V control circuit\u003c\/li\u003e\n\u003cli\u003eOil pump motor included\u003c\/li\u003e\n\u003cli\u003eBlower motor system\u003c\/li\u003e\n\u003cli\u003eProfessional electrical package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Construction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty pressure vessel design\u003c\/li\u003e\n\u003cli\u003eProven Cleaver Brooks engineering\u003c\/li\u003e\n\u003cli\u003eDurable steel construction\u003c\/li\u003e\n\u003cli\u003eProfessional-grade components\u003c\/li\u003e\n\u003cli\u003eLong service life design\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance requirements\u003c\/li\u003e\n\u003cli\u003eIndustrial reliability\u003c\/li\u003e\n\u003cli\u003eCommercial quality throughout\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Compliance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e150 PSI ASME design pressure\u003c\/li\u003e\n\u003cli\u003eFactory safety controls installed\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003eCode-compliant construction\u003c\/li\u003e\n\u003cli\u003eProfessional safety engineering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSYSTEM COMPONENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Boiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaver Brooks Model CB-600-600\u003c\/li\u003e\n\u003cli\u003eSerial Number L-66078\u003c\/li\u003e\n\u003cli\u003eDate 1\/23\/79\u003c\/li\u003e\n\u003cli\u003e600 horsepower rating\u003c\/li\u003e\n\u003cli\u003ePackaged boiler design\u003c\/li\u003e\n\u003cli\u003e25,106,000 BTU\/HR capacity\u003c\/li\u003e\n\u003cli\u003e150 PSI MAWP\u003c\/li\u003e\n\u003cli\u003eComplete with all trim\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBurner System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil-fired burner assembly\u003c\/li\u003e\n\u003cli\u003eForced draft combustion\u003c\/li\u003e\n\u003cli\u003eOil train components\u003c\/li\u003e\n\u003cli\u003eSafety shut-off valves\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eOil pressure monitoring\u003c\/li\u003e\n\u003cli\u003eProfessional burner management\u003c\/li\u003e\n\u003cli\u003e167.5 GPH oil consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControl Systems:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated control panel\u003c\/li\u003e\n\u003cli\u003eBurner management system\u003c\/li\u003e\n\u003cli\u003eFlame safeguard controls\u003c\/li\u003e\n\u003cli\u003eOperational diagnostics\u003c\/li\u003e\n\u003cli\u003eTemperature controls\u003c\/li\u003e\n\u003cli\u003ePressure monitoring\u003c\/li\u003e\n\u003cli\u003eSafety interlocks\u003c\/li\u003e\n\u003cli\u003e120V control circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Components:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e208V 3-phase power supply (99A)\u003c\/li\u003e\n\u003cli\u003e120V control circuit (7A)\u003c\/li\u003e\n\u003cli\u003eOil pump motor (208V)\u003c\/li\u003e\n\u003cli\u003eBlower motor system\u003c\/li\u003e\n\u003cli\u003eAir compressor motor\u003c\/li\u003e\n\u003cli\u003eOil heater system\u003c\/li\u003e\n\u003cli\u003eAll wiring and connections\u003c\/li\u003e\n\u003cli\u003eCircuit protection provisions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; Instrumentation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003ePressure gauge\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eWater level controls\u003c\/li\u003e\n\u003cli\u003eOil pressure monitoring\u003c\/li\u003e\n\u003cli\u003eFlame supervision\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWater System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFeedwater connections\u003c\/li\u003e\n\u003cli\u003eWater level controls\u003c\/li\u003e\n\u003cli\u003eBlowdown valves\u003c\/li\u003e\n\u003cli\u003ePiping connections\u003c\/li\u003e\n\u003cli\u003eDrain connections\u003c\/li\u003e\n\u003cli\u003eLevel indication\u003c\/li\u003e\n\u003cli\u003eLow water protection\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNote: No deaerator tank included\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOil System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil pump motor (208V)\u003c\/li\u003e\n\u003cli\u003eOil heater system\u003c\/li\u003e\n\u003cli\u003eManual oil valve\u003c\/li\u003e\n\u003cli\u003eSafety shut-off valves\u003c\/li\u003e\n\u003cli\u003eOil pressure switches\u003c\/li\u003e\n\u003cli\u003eOil train assembly\u003c\/li\u003e\n\u003cli\u003eSafety interlocks\u003c\/li\u003e\n\u003cli\u003e167.5 GPH rating\u003c\/li\u003e\n\u003cli\u003eProfessional oil components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting System:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy-duty boiler skid\u003c\/li\u003e\n\u003cli\u003ePreviously trailer-mounted\u003c\/li\u003e\n\u003cli\u003eNow configured for stationary installation\u003c\/li\u003e\n\u003cli\u003eStructural steel base\u003c\/li\u003e\n\u003cli\u003eFoundation mounting provisions\u003c\/li\u003e\n\u003cli\u003eProfessional dismounting completed\u003c\/li\u003e\n\u003cli\u003eReady for permanent installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS SUMMARY\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBoiler:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Cleaver Brooks Division, Aqua-Chem, Inc.\u003c\/li\u003e\n\u003cli\u003eLocation: Milwaukee, Wisconsin, USA\u003c\/li\u003e\n\u003cli\u003eModel: CB-600-600\u003c\/li\u003e\n\u003cli\u003eSerial No: L-66078\u003c\/li\u003e\n\u003cli\u003eDate: 1\/23\/79\u003c\/li\u003e\n\u003cli\u003eType: CB Packaged steam boiler\u003c\/li\u003e\n\u003cli\u003eFuel: Oil\u003c\/li\u003e\n\u003cli\u003eInput: 25,106,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eHorsepower: 600 HP\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eOil Consumption: 167.5 GPH\u003c\/li\u003e\n\u003cli\u003eOrigin: USA\u003c\/li\u003e\n\u003cli\u003eASME Certified: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFuel Supply:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuel Type: Oil\u003c\/li\u003e\n\u003cli\u003eOil Consumption: 167.5 GPH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Supply: 208V, 3-Ph, 60 Hz, 99A\u003c\/li\u003e\n\u003cli\u003eMin Circuit: 114 Amps\u003c\/li\u003e\n\u003cli\u003eMax Protection: 396 Amps\u003c\/li\u003e\n\u003cli\u003eControl: 120V, 1-Ph, 60 Hz, 7A\u003c\/li\u003e\n\u003cli\u003eOil Pump: 208V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevious: Trailer-mounted\u003c\/li\u003e\n\u003cli\u003eCurrent: Standalone unit\u003c\/li\u003e\n\u003cli\u003eMounting: Skid-mounted\u003c\/li\u003e\n\u003cli\u003eInstallation: Stationary\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eADDITIONAL INFORMATION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e Used - 1979 Manufacture, Removed from Trailer Configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Cleaver Brooks Division, Aqua-Chem, Inc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Location:\u003c\/strong\u003e Milwaukee, Wisconsin, USA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e CB Packaged Boiler\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CB-600-600\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Number:\u003c\/strong\u003e L-66078\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDate Built:\u003c\/strong\u003e 1\/23\/79\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuel Type:\u003c\/strong\u003e Oil\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBTU Input:\u003c\/strong\u003e 25,106,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower Rating:\u003c\/strong\u003e 600 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Allowable Working Pressure:\u003c\/strong\u003e 150 PSI\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOil Consumption:\u003c\/strong\u003e 167.5 GPH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Power Supply: 208V, 3-Phase, 60 Hz, 99 Amps\u003c\/li\u003e\n\u003cli\u003eMinimum Circuit Ampacity: 114 Amps\u003c\/li\u003e\n\u003cli\u003eMaximum Rating of Circuit Protection: 396 Amps\u003c\/li\u003e\n\u003cli\u003eControl Circuit: 120V, 1-Phase, 60 Hz, 7 Amps\u003c\/li\u003e\n\u003cli\u003eOil Pump Motor: 208V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eControl System:\u003c\/strong\u003e Integrated burner management and control panel\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBurner System:\u003c\/strong\u003e Oil-fired burner assembly\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrevious Configuration:\u003c\/strong\u003e Trailer-mounted mobile unit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Configuration:\u003c\/strong\u003e Standalone stationary boiler on skid\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003eFlame supervision system\u003c\/li\u003e\n\u003cli\u003eMultiple safety interlocks\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown capability\u003c\/li\u003e\n\u003cli\u003ePressure relief protection\u003c\/li\u003e\n\u003cli\u003eOil pressure monitoring\u003c\/li\u003e\n\u003cli\u003eProfessional safety controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePreviously housed in mobile trailer\u003c\/li\u003e\n\u003cli\u003eProfessionally removed from trailer configuration\u003c\/li\u003e\n\u003cli\u003eNow available as standalone stationary unit\u003c\/li\u003e\n\u003cli\u003eSkid-mounted for foundation installation\u003c\/li\u003e\n\u003cli\u003eAll boiler components intact\u003c\/li\u003e\n\u003cli\u003eReady for permanent installation\u003c\/li\u003e\n\u003cli\u003eRequires site preparation and foundation\u003c\/li\u003e\n\u003cli\u003eProfessional rigging recommended for installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaver Brooks CB Packaged Boiler design\u003c\/li\u003e\n\u003cli\u003e1979 year of manufacture\u003c\/li\u003e\n\u003cli\u003e600 horsepower industrial capacity\u003c\/li\u003e\n\u003cli\u003e25,106,000 BTU\/HR input rating\u003c\/li\u003e\n\u003cli\u003e150 PSI maximum working pressure\u003c\/li\u003e\n\u003cli\u003eOil-fired operation\u003c\/li\u003e\n\u003cli\u003eOil consumption rated 167.5 GPH\u003c\/li\u003e\n\u003cli\u003eASME construction and certification\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial-grade construction\u003c\/li\u003e\n\u003cli\u003eComplete factory-packaged assembly\u003c\/li\u003e\n\u003cli\u003eIntegrated burner and control systems\u003c\/li\u003e\n\u003cli\u003eProfessional electrical package (208V 3-phase)\u003c\/li\u003e\n\u003cli\u003e99 amp main power rating\u003c\/li\u003e\n\u003cli\u003e114 amp minimum circuit ampacity\u003c\/li\u003e\n\u003cli\u003e396 amp maximum circuit protection\u003c\/li\u003e\n\u003cli\u003e120V control circuit (7 amps)\u003c\/li\u003e\n\u003cli\u003eOil pump motor included\u003c\/li\u003e\n\u003cli\u003eBlower motor system\u003c\/li\u003e\n\u003cli\u003eOil heater system\u003c\/li\u003e\n\u003cli\u003eAll safety trim and controls installed\u003c\/li\u003e\n\u003cli\u003eLow water cutoff protection\u003c\/li\u003e\n\u003cli\u003eFlame safeguard system\u003c\/li\u003e\n\u003cli\u003eSafety relief valve\u003c\/li\u003e\n\u003cli\u003ePreviously trailer-mounted configuration\u003c\/li\u003e\n\u003cli\u003eRemoved from trailer for stationary use\u003c\/li\u003e\n\u003cli\u003eSkid-mounted for permanent installation\u003c\/li\u003e\n\u003cli\u003eFoundation mounting ready\u003c\/li\u003e\n\u003cli\u003eProven Cleaver Brooks reliability\u003c\/li\u003e\n\u003cli\u003eMilwaukee, Wisconsin USA manufacturing\u003c\/li\u003e\n\u003cli\u003eReady for oil connection and startup\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler only - no deaerator (DA) tank included\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePreviously mobile trailer configuration, now stationary\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eProfessional-grade commercial\/industrial construction\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":46266275528844,"sku":"BSCB600HP266","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-cleaver-brooks-600-hp-150-psi-packaged-steam-boiler-cb-600-600.jpg?v=1770818169","url":"https:\/\/boilers.com\/products\/cleaver-brooks-600hp-150psi-packaged-steam-boiler-cb-600-600","provider":"Boilers.com","version":"1.0","type":"link"}