{"product_id":"cleaver-brooks-100hp-150psi-cbw-700-100-150-st-steam-boiler-natural-gas-1995","title":"Cleaver Brooks 100HP 150PSI CBW-700-100-150-ST Steam Boiler Natural Gas 1995","description":"\u003cp\u003eOVERVIEW\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNOTE: This is a 100 boiler horsepower, 4-pass wetback scotch marine firetube steam boiler manufactured by Cleaver Brooks Division of Aqua-Chem, Inc. in 1995. Rated at 150 PSI maximum working pressure. Natural gas fired. Serial Number L-00322. Skid-mounted with control panel included. Ready for inspection — contact us to schedule.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCleaver Brooks Model CBW-700-100-150-ST — 100 HP, 4-Pass Wetback Scotch Marine Firetube Steam Boiler. Serial Number L-00322, Date 1995. Rated at 150 PSI maximum working pressure with 4,200,000 BTU\/HR natural gas input, 3,450 Lbs.\/Hr. steam capacity, and 500 Sq. Ft. of heating surface. 48-inch shell diameter. The CBW series is one of Cleaver-Brooks' most recognized packaged boiler lines, built at their Milwaukee, Wisconsin facility under the Aqua-Chem, Inc. division.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eControl panel included. Skid-mounted for ease of installation and transport. Burner assembly with 5 HP blower motor included.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIdeal for facility heating, process steam, hospital or institutional steam, food and beverage processing, manufacturing operations, or any application requiring reliable high-pressure steam generation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eEQUIPMENT SPECIFICATIONS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eBoiler Model Information:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Cleaver-Brooks Division, Aqua-Chem, Inc.\u003c\/li\u003e\n\u003cli\u003eOrigin: Milwaukee, Wisconsin, USA\u003c\/li\u003e\n\u003cli\u003eModel Number: CBW-700-100-150-ST\u003c\/li\u003e\n\u003cli\u003eSerial Number: L-00322\u003c\/li\u003e\n\u003cli\u003eDate: 1995\u003c\/li\u003e\n\u003cli\u003eBoiler Type: 4-Pass Wetback Scotch Marine Firetube\u003c\/li\u003e\n\u003cli\u003eFuel Type: Natural Gas Only (700 Series)\u003c\/li\u003e\n\u003cli\u003eReference Form: 118-A-331\u003c\/li\u003e\n\u003cli\u003eManual: 750-150\u003c\/li\u003e\n\u003cli\u003eDrawing: 118-200-B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eModel Number Decoded:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCBW = CB Wetback Design\u003c\/li\u003e\n\u003cli\u003e700 = Gas Only (no oil capability)\u003c\/li\u003e\n\u003cli\u003e100 = 100 Boiler Horsepower\u003c\/li\u003e\n\u003cli\u003e150 = 150 PSI Design Pressure\u003c\/li\u003e\n\u003cli\u003eST = Steam\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePerformance Ratings:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler Horsepower: 100 HP\u003c\/li\u003e\n\u003cli\u003eMax. Working Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eGas Input: 4,200,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eSteam Capacity: 3,450 Lbs.\/Hr.\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 500 Sq. Ft.\u003c\/li\u003e\n\u003cli\u003eShell Diameter: 48 in.\u003c\/li\u003e\n\u003cli\u003eEstimated Efficiency: ~82%\u003c\/li\u003e\n\u003cli\u003eGas Consumption: 4,200 CFH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eElectrical Specifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMain Power Supply: 220V, 3 Phase, 60 Hz, 17.5 Amp\u003c\/li\u003e\n\u003cli\u003eMinimum Circuit Ampacity: 21.50 Amp\u003c\/li\u003e\n\u003cli\u003eMax. Rating of Circuit Protection: 60.00 Amp\u003c\/li\u003e\n\u003cli\u003eBlower Motor: 5 HP\u003c\/li\u003e\n\u003cli\u003eControl Circuit: 120V, 1 Phase, 60 Hz, 7 Amp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eKEY FEATURES \u0026amp; BENEFITS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCleaver Brooks Quality Manufacturing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProven CBW Series 4-pass wetback scotch marine firetube design\u003c\/li\u003e\n\u003cli\u003e100 HP industrial capacity\u003c\/li\u003e\n\u003cli\u003e4,200,000 BTU\/HR natural gas input\u003c\/li\u003e\n\u003cli\u003e3,450 Lbs.\/Hr. steam output at 150 PSI\u003c\/li\u003e\n\u003cli\u003eHeavy-duty commercial\/industrial construction\u003c\/li\u003e\n\u003cli\u003eBuilt 1995 — Cleaver Brooks Milwaukee production\u003c\/li\u003e\n\u003cli\u003eListed gas fired boiler assembly per nameplate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e4-Pass Wetback Scotch Marine Firetube Design:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHot combustion gases make four full passes through the boiler before exiting\u003c\/li\u003e\n\u003cli\u003eMaximizes heat extraction and thermal efficiency\u003c\/li\u003e\n\u003cli\u003eFully water-jacketed wetback turnaround chamber\u003c\/li\u003e\n\u003cli\u003eEliminates expensive refractory maintenance associated with dryback designs\u003c\/li\u003e\n\u003cli\u003eLower operating and maintenance costs versus dryback configurations\u003c\/li\u003e\n\u003cli\u003e~82% estimated thermal efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNatural Gas Firing (700 Series):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas only — no oil train complexity\u003c\/li\u003e\n\u003cli\u003eSimplified fuel system with lower maintenance requirements\u003c\/li\u003e\n\u003cli\u003e4,200,000 BTU\/HR maximum input\u003c\/li\u003e\n\u003cli\u003eClean-burning fuel — reduced fouling and maintenance intervals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eControl Panel Included:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated boiler control panel mounted alongside unit\u003c\/li\u003e\n\u003cli\u003eMultiple indicator lights (burner status, alarm, operational)\u003c\/li\u003e\n\u003cli\u003eIntegrated safety interlock controls\u003c\/li\u003e\n\u003cli\u003eProfessional panel enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSkid-Mounted Package:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounted on structural steel skid\u003c\/li\u003e\n\u003cli\u003eEasy rigging, transport, and installation\u003c\/li\u003e\n\u003cli\u003eSelf-contained package ready for utility connections\u003c\/li\u003e\n\u003cli\u003ePhotos show unit on flatbed trailer — transport-ready configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSYSTEM COMPONENTS\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMain Boiler:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCleaver Brooks Model CBW-700-100-150-ST\u003c\/li\u003e\n\u003cli\u003eSerial Number L-00322\u003c\/li\u003e\n\u003cli\u003e100 HP, 150 PSI, 3,450 Lbs.\/Hr. steam capacity\u003c\/li\u003e\n\u003cli\u003e500 Sq. Ft. heating surface, 48 in. shell diameter\u003c\/li\u003e\n\u003cli\u003e4-pass wetback scotch marine firetube design\u003c\/li\u003e\n\u003cli\u003eComplete with all trim and controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eBurner System:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNatural gas burner assembly — factory mounted\u003c\/li\u003e\n\u003cli\u003e5 HP blower motor\u003c\/li\u003e\n\u003cli\u003eGas train and safety shut-off valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eControl Panel:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated boiler control panel included\u003c\/li\u003e\n\u003cli\u003eMultiple status\/alarm indicator lights\u003c\/li\u003e\n\u003cli\u003eSafety interlock system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eMounting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStructural steel skid base\u003c\/li\u003e\n\u003cli\u003eAll major components skid-mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS SUMMARY\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Cleaver-Brooks Division, Aqua-Chem, Inc.\u003c\/li\u003e\n\u003cli\u003eModel: CBW-700-100-150-ST\u003c\/li\u003e\n\u003cli\u003eSerial No.: L-00322\u003c\/li\u003e\n\u003cli\u003eDate: 1995\u003c\/li\u003e\n\u003cli\u003eType: 4-Pass Wetback Scotch Marine Firetube\u003c\/li\u003e\n\u003cli\u003eFuel: Natural Gas Only\u003c\/li\u003e\n\u003cli\u003eCapacity: 100 BoHP\u003c\/li\u003e\n\u003cli\u003eMax. Working Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eGas Input: 4,200,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eSteam Capacity: 3,450 Lbs.\/Hr.\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 500 Sq. Ft.\u003c\/li\u003e\n\u003cli\u003eShell Diameter: 48 in.\u003c\/li\u003e\n\u003cli\u003eBlower Motor: 5 HP\u003c\/li\u003e\n\u003cli\u003eMain Power: 220V, 3 Phase, 60 Hz, 17.5 Amp\u003c\/li\u003e\n\u003cli\u003eControl Circuit: 120V, 1 Phase, 60 Hz, 7 Amp\u003c\/li\u003e\n\u003cli\u003eControl Panel: Included\u003c\/li\u003e\n\u003cli\u003eMounting: Skid-Mounted\u003c\/li\u003e\n\u003cli\u003eOrigin: Milwaukee, WI, USA\u003c\/li\u003e\n\u003cli\u003eCondition: Used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eADDITIONAL INFORMATION\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCondition: Used\u003c\/li\u003e\n\u003cli\u003eYear Built: 1995\u003c\/li\u003e\n\u003cli\u003eManufacturer: Cleaver-Brooks Division, Aqua-Chem, Inc.\u003c\/li\u003e\n\u003cli\u003eModel: CBW-700-100-150-ST\u003c\/li\u003e\n\u003cli\u003eSerial Number: L-00322\u003c\/li\u003e\n\u003cli\u003eBoiler Type: 4-Pass Wetback Scotch Marine Firetube\u003c\/li\u003e\n\u003cli\u003eCapacity: 100 HP\u003c\/li\u003e\n\u003cli\u003eMax. Working Pressure: 150 PSI\u003c\/li\u003e\n\u003cli\u003eGas Input: 4,200,000 BTU\/HR\u003c\/li\u003e\n\u003cli\u003eSteam Capacity: 3,450 Lbs.\/Hr.\u003c\/li\u003e\n\u003cli\u003eHeating Surface: 500 Sq. Ft.\u003c\/li\u003e\n\u003cli\u003eFuel: Natural Gas Only\u003c\/li\u003e\n\u003cli\u003eBlower Motor: 5 HP\u003c\/li\u003e\n\u003cli\u003eMain Power: 220V, 3 Phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eControl Panel: Included\u003c\/li\u003e\n\u003cli\u003eMounting: Skid-Mounted on Structural Steel Skid\u003c\/li\u003e\n\u003cli\u003eOrigin: Milwaukee, WI, USA\u003c\/li\u003e\n\u003cli\u003eInspection: Welcome — contact us to schedule\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIMPORTANT NOTES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl panel and burner assembly included with boiler\u003c\/li\u003e\n\u003cli\u003eNatural gas only — no oil capability (700 Series)\u003c\/li\u003e\n\u003cli\u003eSkid-mounted — professional rigging recommended for loading and transport\u003c\/li\u003e\n\u003cli\u003eBuyer responsible for transport arrangements from current location\u003c\/li\u003e\n\u003cli\u003eContact us for additional photos, video walkthroughs, or technical questions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Boilers.com","offers":[{"title":"Default Title","offer_id":46881470120076,"sku":"BSCB100HP290","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/9838\/9644\/files\/large-used-cleaver-brooks-100-hp-150-psi-cbw-700-100-150-st-steam-boiler-natural-gas-1995.jpg?v=1774439226","url":"https:\/\/boilers.com\/products\/cleaver-brooks-100hp-150psi-cbw-700-100-150-st-steam-boiler-natural-gas-1995","provider":"Boilers.com","version":"1.0","type":"link"}