50 HP Fulton Boiler VSRT-50 Firetube Steam Boiler #BSF50HP3002

Stock #: BSF50HP3002

Specifications

ManufacturerFulton Boiler
ModelVSRT-50
TypeFiretube
Horsepower50 HP
Design Pressure150 PSI
OutputSteam
FuelNatural Gas
Year Built2022
ConditionUsed
PriceCall for Price
LocationMiami, FL
AvailabilityAvailable
Stock NumberBSF50HP3002

Description

OVERVIEW

This sale includes the Fulton feedwater tank skid shown in the photos, along with the boiler.

2022 Fulton VSRT-50 Vertical Spiral Rib Tubeless steam boiler, 50 HP, 150 PSI MAWP, natural gas fired, with a Fulton feedwater tank. Nameplate rating is 1,674,000 BTU/hr output and 1,993,000 BTU/hr input at 0–1,999 ft. Fulton rates the VSRT-50 at 1,725 lb/hr steam from and at 212°F. The boiler is currently installed in a boiler room in Miami, FL, so removal and rigging will be needed. Photos show a Fulton VSRT control panel, a forced-draft burner with blower motor, a cyclonic air inlet silencer, and a separate Fulton feedwater tank skid with its own control panel, pumps, and disconnect. Tank size is not marked on the photos. Built by Fulton Thermal Corporation / Fulton Steam Solutions, Inc., Pulaski, NY.

EQUIPMENT SPECIFICATIONS

  • Manufacturer: Fulton Thermal Corporation / Fulton Steam Solutions, Inc. (Pulaski, NY)
  • Product line: Vertical Spiral Rib Tubeless (VSRT) steam boiler
  • Model: VSRT-50
  • National Board No.: 10689
  • CRN: N/A
  • Year built: 2022 (Manufacturer's Data Report; year is blank on the nameplate)
  • Type: steam, vertical spiral rib tubeless, ASME Section I
  • Fuel: natural gas
  • Shell thickness: .394 in
  • Head thickness: .394 in
  • Heating surface: 116 sq ft (Manufacturer's Data Report; also Fulton VSRT-50 data)
  • MAWP: 150 PSI (Manufacturer's Data Report; not stamped on the nameplate)
  • Shop hydrostatic test: 225 PSI (Manufacturer's Data Report)
  • Mounting: skid (Manufacturer's Data Report)
  • Location: Miami, FL
  • Dimensions (Fulton VSRT-50 2023 brochure, standard configuration): about 97 in high without trim, 107 in with trim, 130 in with burner pull; 49 in wide without trim, 68 in with trim; 83 in deep
  • Weights (Fulton VSRT-50 technical data sheet, standard configuration): 6,000 lb dry, 8,777 lb operating, 9,513 lb flooded; 333 gal water volume at normal working level
  • Connections (Fulton VSRT-50 technical data sheet / data report): 4 in steam outlet, 1 in feedwater, 1-1/2 in bottom blowdown, 3/4 in surface blowdown, 3/4 in high-water protection, 1-1/2 in gas train inlet, 6 in combustion air inlet, 10 in stack; 150 PSI trim safety valve 1 in x 1-1/4 in

Performance Ratings

  • Boiler horsepower: 50 BHP (Fulton VSRT-50 data sheet; matches the nameplate output)
  • Rated steam output: 1,725 lb/hr from and at 212°F (Fulton VSRT-50 data sheet)
  • Maximum designed steaming capacity: 2,070 lb/hr (Manufacturer's Data Report)
  • BTU output: 1,674,000 BTU/hr (nameplate)
  • Max BTU input (0 to 1,999 ft): 1,993,000 BTU/hr (nameplate)
  • Max BTU input (2,000 ft and above): blank on nameplate
  • Minimum input at low fire (Fulton data sheet): 249,000 BTU/hr, 8:1 turndown
  • Natural gas usage at rated input (Fulton data sheet): about 1,993 SCFH
  • Efficiency, emissions: Fulton lists operating efficiencies up to 86% and low NOx below 20 ppm for the VSRT series. Not specified for this individual unit.

Burner System

  • Forced-draft natural gas burner with blower motor and cyclonic air inlet silencer; Fulton lists a fully modulating 8:1 turndown burner for the VSRT-50
  • Gas supply pressure: 3.0 in WC min, 13.8 in WC max
  • Manifold gas pressure: -2.4 in WC min, -5.56 in WC max
  • Boiler electrical: 460 V / 60 Hz / 3 PH, 17 FLA
  • Controls rating: blank on nameplate
  • Water pump motor rating: blank on the boiler nameplate (the feedwater tank skid has its own panel and pumps)

ADDITIONAL INFORMATION

  • Condition: used, currently installed; removal and rigging required
  • Included equipment: Fulton feedwater tank skid with its own Fulton control panel, pumps, and disconnect, as shown in the photos. Tank capacity is not marked.
  • Operating hours, service history, and inspection records: not specified
  • Manufacturer's Data Report notes (same National Board number): 150 PSI MAWP, 116 sq ft heating surface, 2,070 lb/hr maximum designed steaming capacity, pressure relief valve 1 in x 1-1/4 in set at 150 PSI with 2,585 lb/hr relieving capacity. The Form P-2 header reads "VSRT-60 150#." The nameplate is stamped VSRT-50, and the stamped input and output match Fulton's published VSRT-50 ratings. Fulton's current literature shows the VSRT-50 and VSRT-60 sharing the same vessel size and 116 sq ft heating surface. This listing follows the nameplate as a 50 HP VSRT-50.

Specifications marked as coming from Fulton literature are for standard VSRT-50 configurations and may differ slightly on this 2022 build.

Yard tag: BSF50HP3002

Request a Quote

Interested in this boiler? Send us a message and we’ll get back to you with pricing, availability, and shipping options.

Contact Form Demo

What happens next

  1. Send your request — takes about a minute.
  2. Hear back within 24 hours with pricing, full specs, and current availability.
  3. We handle the logistics — rigging, freight, and delivery anywhere in the country.
Prefer to talk it through? 305-428-2777 Industrial boiler specialists — serving industry since 2000